Analysis of the distribution of mechanical load on the plate and lateral hinge of a valgus-producing open wedge high tibial osteotomy during weight-bearing by simulating consolidation. Finite element study - 22/12/24

Doi : 10.1016/j.otsr.2024.104115 
Samuel Berthe a, Henri Favreau b, Karl Boulos b, Matthieu Ollivier c, Nadia Bahlouli a, Mekki Tamir b, Matthieu Ehlinger a, b,
a Laboratoire ICube, Université de Strasbourg – CNRS, 4 rue de la Manufacture des Tabacs, 67000 Strasbourg, France 
b Service de Chirurgie Orthopédique et de Traumatologie, Hôpital de Hautepierre II, 1 Avenue Molière, 67098 Strasbourg Cedex, France 
c Département de Chirurgie Orthopédique, Hôpital Sainte-Marguerite, Hôpital Universitaire de Marseille, 270 Boulevard Sainte Marguerite, 13009 Marseille, France 

Corresponding author.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Sunday 22 December 2024

Abstract

Introduction

High tibial osteotomy (HTO) is indicated for managing isolated medial knee osteoarthritis in a young patient with a metaphyseal deformity of the proximal tibia. In a medial open-wedge HTO, maintaining the integrity of the hinge is crucial for consolidation and preservation of the correction. Based on a validated model and preliminary results, the objective of this work was to measure and monitor the distribution of mechanical load on a locking fixation plate and the lateral hinge of an HTO using a finite element (FE) model during different phases of consolidation evolution, simulating single leg weightbearing.

Hypothesis

The working hypothesis was that with increasing consolidation, the stresses significantly decrease on both the plate and the lateral hinge, but with greater magnitudes on the plate and approaching zero on the hinge.

Materials and methods

A validated numerical model of a high tibial osteotomy (HTO) fixed with a locking plate on a real proximal tibial geometry (using Autodesk Fusion 360 and Altair HyperWorks software) was used. An axial load equivalent to one body weight was applied. Five scenarios were considered, resulting in five different models by varying, in the FE model, the Young's modulus of the trabecular and cortical bone, which allows for simulating the evolution of consolidation. Consolidation scenarios were tested by varying the mechanical properties of the HTO gap filling: 25% of normal bone properties, then 50%, 75%, and finally 100%, which is hypothetically considered as remodeled bone. The primary outcome measure was the maximum stress value in the areas of interest (Von Mises stresses, in MPa), specifically at the plate and lateral hinge.

Results

The decrease (in %) is major as early as the simulation of 25% consolidation in both areas of interest: a reduction of 91% on the plate and 93% on the hinge. The reduction in absorbed stresses continues in both areas, but with a more pronounced decrease on the plate. It is noteworthy that from 50% consolidation, under these experimental conditions, stresses remain comparable on the hinge, especially between 75% and 100% consolidation.

Discussion

The hypothesis is confirmed with a more marked decrease on the plate and approaching zero on the hinge, which seems logical in a consolidation process. Comparison with the literature is challenging, as only one finite element study has analyzed the influence of consolidation on the stresses absorbed by an HTO plate, but with different consolidation thresholds and without studying the hinge. This study has limitations: the model construction conditions, it is a finite element computer study, and the weight-bearing simulation for this study was static, which does not address the distribution of stresses during walking, this model is defined for a given valgus HTO plate and a specific opening and does not allow for extrapolation to distal femur opening osteotomies nor in clinical practice.

Conclusion

The hypothesis is confirmed; however, further studies are needed to validate these numerical results: an experimental part on instrumented cadaveric bone and comparative studies of fixation plates are necessary.

Level of evidence

V; expert opinion, controlled laboratory study.

Le texte complet de cet article est disponible en PDF.

Keywords : Hinge, Tibial osteotomy, Finite elements, Simulation


Plan


© 2024  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.