S'abonner

Development and validity evidence of an interactive 3D model for thoracic and lumbar spinal fractures pedagogy: a first step of validity study - 11/12/24

Doi : 10.1016/j.otsr.2024.104084 
Léonard Swann Chatelain a, , Emmanuelle Ferrero a, Pierre Guigui a, Christian Garreau de Loubresse a, Dan Benhamou b, c, Antonia Blanié b, c
a Hôpital Européen Georges Pompidou (HEGP), Department of Orthopedic Surgery, Paris, France 
b Hôpital du Kremlin-Bicêtre, Department of Anesthesia, Intensive Care and Perioperative Medicine, Le Kremlin-Bicêtre, France 
c Simulation Center LabForsSIMS, Bicêtre Medical School, Paris-Saclay University, Le Kremlin-Bicêtre, France 

Corresponding author.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Wednesday 11 December 2024

Abstract

Background

Thoracic and lumbar spinal fractures are common in trauma care, requiring accurate classification to guide appropriate treatment. While traditional teaching methods use static 2D images, there is a growing need for interactive tools to improve understanding. This study addresses the lack of interactive three-dimensional (3D) models for teaching the AO (Arbeitsgemeinschaft für Osteosynthesefragen) Spine classification for thoracic and lumbar fractures.

Hypothesis

A free and open-access interactive 3D model of thoracic and lumbar spinal fractures was developed. The study aimed to provide preliminary validity evidence. We hypothesized that this model would be a valid educational tool for teaching the AO Spine classification, receiving high scores from senior spine surgeons on a validation questionnaire regarding anatomical realism and pedagogical value. The primary endpoint was the percentage of surgeons rating the model ≥8/10 on the Likert scale for content validation. We hypothesized that the 3D model would be validated by at least 75% of participating senior spine surgeons (rating ≥8/10) for anatomical realism and pedagogical value.

Methods

The 3D model was created using the Blender® software, incorporating CT-scan images of a lumbar spine. AO Spine classification was used to recreate spinal fractures animations. The model could be used on any computer or smartphone, directly online. A total of 24 senior spine surgeons (5 professors, 6 fellows, 8 hospital practitioners, and 5 private practitioners) evaluated the 3D model using a structured questionnaire with seven Likert-scale items, assessing anatomical realism, fracture representation, adherence to the AO Spine classification, pedagogical value, and ease of use. A score of ≥8/10 was considered a positive validation. Group comparisons were made based on hospital activity and age.

Results

The 3D model was positively validated by 92% of surgeons for anatomical realism, 88% for fracture representation, and 92% for adherence to the AO Spine classification. The model’s educational value for junior residents was rated positively by 100% of participants. Six out of 24 surgeons (25%) rated the ease of navigation <8/10. Group comparisons revealed that university-affiliated surgeons rated the model higher overall (mean score 9.25/10) compared to private practitioners, who gave the lowest ratings (mean score 8.6/10). No significant correlation was found between age and ease of navigation (p = 0.948).

Discussion

The developed 3D model of thoracic and lumbar spine fractures is the first of its kind. It provides an innovative, open-access and freely online accessible tool for teaching the AO Spine classification. The findings demonstrate that it is a valid pedagogical tool for teaching the AO Spine classification, with strong support for its anatomical accuracy and pedagogical effectiveness. This study sets the stage for a future validation study with surgical residents.

Level of evidence

III.

Le texte complet de cet article est disponible en PDF.

Keywords : Vertebral fracture, Assessment, Validity evidence, Messick’s framework, Pedagogy


Plan


© 2024  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.