S'abonner

Diagnostic performance of various imaging modalities in localizing ectopic ACTH syndrome: A systematic review - 23/11/24

Doi : 10.1016/j.ando.2024.07.001 
Chethan Yami Channaiah a, Saba Samad Memon a, Anurag Ranjan Lila a, Vijaya Sarathi b, Manjiri Karlekar a, Rohit Barnabas a, Virendra Ashokrao Patil a, Anima Sharma a, Aditya Phadte a, Gaurav Malhotra c, Nalini shah a, Tushar Bandgar a,
a Department of Endocrinology, Seth GS Medical College, KEM Hospital, 400012 Parel, Mumbai, India 
b Department of Endocrinology, Vydehi Institute of Medical Sciences and Research Centre, 560066 Bengaluru, India 
c Radiation medical Centre, Bhabha Atomic Research Centre, 400012 Mumbai, India 

*Corresponding author.

Abstract

Background

To elucidate the role of various imaging modalities for tumor localization in ectopic ACTH Cushing's syndrome (EAS).

Design and method

Systematic review of the literature published between January 2015–2024 was performed. Patients (290 EAS patients, 23.8% Occult) who underwent contrast enhanced CT (CECT) and at least one PET/CT-scan (68Ga-SSTR, FDG and/or F-DOPA) were included.

Results

The sensitivity for identifying EAS tumor was comparable across CECT (63.1%, n=290), SSTR-PET/CT (58.2%, n=187), and FDG-PET/CT (57.6%, n=191), but was poor for DOPA-PET/CT (30.8%, n=26). Sensitivity for detecting metastasis was also comparable across CECT (78%, n=73), SSTR-PET/CT (85.3%, n=41), and FDG-PET (73.7%, n=38). For localised lesions, sensitivity as per etiology and grade of NET were similar for three scans, with exception of Thymic NET and grade 1 NET where CECT was better than FDG PET/CT. In patients not localised on CECT, sensitivity of SSTR PET/CT was 33.3% (vs. 18.9% FDG-PET/CT) whereas for patients negative on CECT and FDG-PET, sensitivity of SSTR-PET/CT was 15%. In cases where CECT and SSTR-PET/CT failed to localize, the sensitivities of FDG-PET/CT and DOPA-PET/CT were only 5.7% (2/35) and 0% (0/9), respectively. SSTR-PET/CT has a distinct advantage with significantly lesser false positive (FP) lesions (2.6%, mostly in thyroid/or pancreas). In comparison, CECT and FDG-PET/CT had FP ∼11% (mostly in lung and/or mediastinum), most of which were negative on SSTR-PET/CT.

Conclusions

As per the current evidence, SSTR-PET/CT can be considered as the scan of choice in EAS evaluation, and further research is needed as one-fourth of the lesions remain occult.

Le texte complet de cet article est disponible en PDF.

Keywords : Ectopic ACTH syndrome, PET/CT in EAS, Imaging modalities in EAS


Plan


© 2024  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 85 - N° 6

P. 596-603 - décembre 2024 Retour au numéro
Article précédent Article précédent
  • Acromegaly: Incidence, patient characteristics and treatment patterns in a 10-year nationwide retrospective hospital cohort study
  • Grégoire Fauchier, Emeline Laurent, Luigi Maione, Anne-Isabelle Lecuyer, Julien Herbert, Peggy Pierre-Renoult, Lucie Cloix, Philippe Chanson, Pierre-Henri Ducluzeau, Leslie Grammatico-Guillon
| Article suivant Article suivant
  • Acute hypercalcemic crisis: A narrative review with a focus on pregnancy
  • Nadia Sabbah

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.