S'abonner

Arthrodèses cunéo-métatarsienne (lapidus modifié) par plaque plantaire pour le traitement de l’hallux valgus : résultats cliniques et radiologiques à un an - 21/11/24

First cuneo-metatarsal arthrodesis (modified lapidus) with plantar plate for the treatment of hallux valgus: Clinical and radiological outcomes at one year follow-up

Doi : 10.1016/j.rcot.2024.07.019 
Ramy Samargandi 1, , 2 , Maxime Saad 1, Rayane Benhenneda 1, Louis-Romée Le Nail 1, Jean Brilhault 1, 3
1 CHRU de Tours, hôpital Trousseau, service de chirurgie orthopédique et traumatologique, avenue de la République, 37170 Chambray-lès-Tours, France 
2 University of Jeddah, Faculty of Medicine, Department of Orthopedic Surgery, Jeddah, Arabie saoudite 
3 Clinique Saint-Léonard, centre de la cheville et du pied, 49800 Trélazé, France 

Ramy Samargandi, CHRU de Tours, hôpital Trousseau, service de chirurgie orthopédique, avenue de la République, Chambray-lès-Tours, 37044 Tours cedex 9, France.CHRU de Tours, hôpital Trousseau, service de chirurgie orthopédiqueavenue de la République, Chambray-lès-ToursTours cedex 937044France

Résumé

Introduction

L’arthrodèse de l’articulation cunéo-métatarsienne du premier rayon (lapidus modifié) est une technique chirurgicale pour le traitement des hallux valgus modérés à sévères, associées à des hypermobilités de la première articulation tarsométatarsienne. L’objectif principal de cette étude était d’étudier le taux de consolidation pour la procédure de lapidus avec une plaque plantaire et un protocole d’appui complet immédiat. Les objectifs secondaires étaient d’étudier les corrections radiologiques et éventuelles complications associées.

Méthodes

Nous avons revu rétrospectivement les dossiers de 66 patients (80 pieds) opérés d’un lapidus modifié pour le traitement d’un hallux valgus associé à une hypermobilité du premier rayon, par un chirurgien senior de notre hôpital entre mai 2013 et novembre 2019 ; tous ont eu un suivi minimum de 12 mois. Les patients ont été évalués à 3 semaines, 3 mois et à 1 an. Les mesures radiologiques étaient réalisées sur une incidence de face dorso-plantaire en charge en préopératoire, à 3 et 12 mois postopératoires.

Résultats

La consolidation osseuse a été acquise dans 79 cas (98,75 %). Il y a eu un cas de pseudarthrodèse, deux complications cicatricielles, deux matériels symptomatiques et une fracture de fatigue. Il n’y a pas eu de cas de récidive. L’angle hallux valgus moyen s’est amélioré de 30,5°±10,4° à 10,1°±6,6° (p<0,001), l’angle intermétatarsien moyen s’est amélioré de 13,4°±3,6° à 5,6°±2,9 (p<0,001). La position moyenne des sésamoïdes est passée du stade 5,9±1,6 au stade 2,6±1,2 (p<0,001). Le raccourcissement moyen du premier métatarsien était de 3,6±1,8mm. Il n’y avait pas de différence significative entre les mesures à 3 et 12 mois postopératoire.

Conclusion

Le lapidus modifié avec plaque plantaire et vis de compression est une technique fiable avec un taux de consolidation élevé, permettant une mise en charge précoce et un taux de complications acceptable.

Niveau d’évidence

IV ; étude rétrospective.

Le texte complet de cet article est disponible en PDF.

Summary

Introduction

The modified lapidus arthrodesis, involving the first cuneo-metatarsal joint, is a well-established surgical method and widely utilized for treating moderate to severe hallux valgus deformities with hypermobility in the first tarsometatarsal joint. The purpose of this study was to assess the rate of union following the lapidus procedure using a plantar plate and an immediate full weight-bearing protocol. Secondary objectives included examining radiological corrections and potential associated complications.

Methods

A retrospective study included 66 patients (80 feet) who underwent a modified Lapidus procedure for the treatment of hallux valgus associated with hypermobility of the first ray, performed by a single senior surgeon at our institution between May 2013 and November 2019. All patients had a minimum follow-up of 12 months. Patients were clinically assessed at 3 weeks, 3 months, and 1 year. Radiological measurements were taken on weight-bearing dorsoplantar views preoperatively, at 3 months, and at 12 months postoperatively.

Results

Bone union was achieved in 79 cases (98.75%). There was one case of non-union, two wound complications (one infection and one dehiscence), two cases of symptomatic hardware requiring hardware removal, and one stress fracture associated with recurrence of hallux valgus that required revision. The mean hallux valgus angle (HVA) improved from 30.5°±10.4° to 10.1°±6.6° (P<0.001), the mean intermetatarsal angle (IMA) improved from 13.4°±3.6° to 5.6°±2.9 (P<0.001), The average sesamoid position improved from stage 5.9±1.6 to stage 2.6±1.2 (P<0.001). The mean shortening of the first metatarsal was 3.6±1.8mm. There was no significant difference between measurements at 3 and 12 months postoperatively.

Conclusion

Modified lapidus with a planter plate and compression screw is a reliable method of fixation with a high union rate, permit an immediate protected weight-bearing and a low complications rate.

Level of evidence

IV; retrospective study.

Le texte complet de cet article est disponible en PDF.

Mots clés : Arthrodèse cunéo-métatarsienne, Hallux valgus, Instabilité, Lapidus modifié, Articulation métatarsophalangienne, Plaque

Keywords : Metatarsocuneiform fusion, Hallux valgus, Instability, Modified lapidus procedure, Metatarsophalangeal joints, Plate


Plan


 Ne pas utiliser, pour citation, la référence française de cet article, mais celle de l’article original paru dans Orthopaedics & Traumatology: Surgery & Research, en utilisant le DOI ci-dessus.


© 2024  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 110 - N° 8

P. 1105-1112 - décembre 2024 Retour au numéro
Article précédent Article précédent
  • Comparaison des résultats de l’arthrodèse métatarso-phalangienne du 1er rayon chez les patients souffrant d’hallux valgus sévère aux reprises d’hallux valgus par plaque verrouillée et vis de compression
  • Dong Tran-Minh, Benoit Poirot-Seynaeve, Tristan Vialla, Xavier Ohl, Saïdou Diallo, Renaud Siboni
| Article suivant Article suivant
  • Le « Patient acceptable symptom state » (PASS) après arthroplastie de résection fémorale proximale et distale
  • Marianne Wiklund, Arthur Gras, Jean-Luc Hanouz, Julien Dunet, Goulven Rochcongar, Christophe Hulet

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.