S'abonner

Advantages of a Data-Capture System with Video to Record Neonatal Resuscitation Interventions - 08/11/24

Doi : 10.1016/j.jpeds.2024.114238 
Lene Nymo Trulsen, MD 1, 2, Arjun Anumula, BS 3, Ana Morales, MPH 3, Claus Klingenberg, MD, PhD 1, 2, Anup C. Katheria, MD 3,
1 Research Group Child and Adolescent Health, Faculty of Health Sciences, UiT-The Arctic University of Norway, Tromsø, Norway 
2 Department of Pediatrics and Adolescence Medicine, University Hospital of North Norway, Tromsø, Norway 
3 Neonatal Research Institute, Sharp Mary Birch Hospital for Women & Newborns, San Diego, CA 

Reprint requests: Anup C. Katheria, MD, Neonatal Research Institute, Sharp Mary Birch Hospital for Women & Newborns, 3003 Health Center Dr, San Diego, CA 92123.Neonatal Research InstituteSharp Mary Birch Hospital for Women & Newborns3003 Health Center DrSan DiegoCA92123

Abstract

Objective

To assess the completeness and accuracy of neonatal resuscitation documentation the electronic medical record (EMR) compared with a data-capture system including video.

Study design

Retrospective observational study of 226 infants assessed for resuscitation at birth between April 2019 and October 2021 at Sharp Mary Birch Hospital, San Diego. Completeness was defined as the presence of documented resuscitative interventions in the EMR. We assessed the timing and frequency of interventions to determine the accuracy of the EMR documentation using video recordings as an objective record for comparison. Inaccuracy of EMR documentation was scored as missing (not documented), under-reported, or over-reported.

Results

Overall, the completeness of resuscitation interventions documented in the EMR was high (85%-100%), but the accuracy of documentation varied between 39% and 100% Modes of respiratory support were accurately captured in 96%-100% of the EMRs. Time to successful intubation (39%) and maximum fraction of inspired oxygen (47%) were the least accurately documented interventions in the EMR. Under-reporting of interventions with several events (eg, number of positive pressure ventilation events and intubation attempts) were also common errors in the EMR.

Conclusions

The self-reported modes of respiratory support were accurately documented in the EMR, whereas the timing of interventions was inaccurate when compared with video recordings. The use of a video-capture system in the delivery room provided a more objective record of the timing of specific interventions during neonatal resuscitations.

Le texte complet de cet article est disponible en PDF.

Keywords : video recording, documentation, delivery room, accuracy, electronic medical record

Abbreviations : CPAP, CPQCC, DR, EMR, FiO2, PEEP, PIP, PPV, RFM


Plan


© 2024  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 275

Article 114238- décembre 2024 Retour au numéro
Article précédent Article précédent
  • Cross-Sectional Evaluation of Health Insurance Knowledge and Self-Efficacy in Adolescents and Young Adults with Inflammatory Bowel Disease
  • Breanna Lopez Cruz, Danielle Rosales, Jonah Chuang, Rusvelda Cruz, Jeannie S. Huang
| Article suivant Article suivant
  • Risk Assessment of Cognitive Impairment at 2 Years of Age in Infants Born Extremely Preterm Using the INTERGROWTH-21st Growth Standards
  • Ariel A. Salas, Waldemar A. Carlo, Carla M. Bann, Edward F. Bell, Tarah T. Colaizy, Noelle Younge, Myriam Peralta, Namasivayam Ambalavanan, Brenda B. Poindexter, Eunice Kennedy Shriver NICHD Neonatal Research Network, Michele C. Walsh, Andrew A. Bremer, Stephanie Wilson Archer

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.