S'abonner

F-waves responses derived from low-intensity electrical stimulation: A method to explore split-hand pathogenesis - 02/11/24

Doi : 10.1016/j.neucli.2024.103018 
Miguel Lopes a, Michael Swash a, b, Mamede de Carvalho a, c,
a Institute of Physiology, Instituto de Medicina Molecular João Lobo Antunes, Centro de Estudos Egas Moniz, Faculdade de Medicina, Universidade de Lisboa, Lisbon, Portugal 
b Departments of Neurology and Neuroscience, Barts and the London School of Medicine, Queen Mary University of London and Royal London Hospital, UK 
c Department of Neurosciences and Mental Health, Hospital de Santa Maria, Centro Hospitalar Universitário de Lisboa Norte, Lisbon, Portugal 

Corresponding author at: Institute of Molecular Medicine, Faculty of Medicine, University of Lisbon, Av. Professor Egas Moniz, 1648-028 Lisbon, Portugal.Institute of Molecular Medicine, Faculty of MedicineUniversity of LisbonAv. Professor Egas MonizLisbon1648-028Portugal

Abstract

Objectives

The “split-hand syndrome” is a common clinical sign in amyotrophic lateral sclerosis (ALS), being characterized by more severe atrophy of the hand muscles on the radial side of the hand compared to the ulnar side. We aimed to investigate possible physiological differences between relevant hand muscles using low-intensity F-wave stimulation to assess spinal motoneuron excitability.

Methods

We recruited 36 healthy volunteers. F-waves were recorded from the abductor pollicis brevis (APB), first dorsal interosseous (FDI) and abductor digiti minimi (ADM), using 20 supramaximal stimuli followed by 20 stimuli at a low-intensity required to obtain M-waves with 10 % amplitude of maximal CMAP. We evaluated the following F-wave parameters: F-M latency, chronodispersion, persistence, amplitude, F/CMAP amplitude ratio and number of F-wave repeaters (with low-intensity). In 10 subjects, low-intensity stimulation F-waves were compared after 20 and 50 stimuli in each muscle.

Results

Low-intensity stimulation resulted in lower F-wave amplitude and persistence and higher F/CMAP amplitude ratios. There were no significant differences in F-wave latencies and chronodispersion. When comparing the three muscles, we found higher F-wave persistence and F/CMAP amplitude ratios when recording over the ADM and APB compared to the FDI. We also found a higher number of F-wave repeaters in the ADM with low-intensity stimulation. Results from 20 to 50 low-intensity stimuli were similar.

Discussion

A small number of low-intensity stimuli is appropriate to study F-wave latencies and chronodispersion. We found differences in some physiological properties of the ADM spinal motoneuron pool compared to other hand muscles.

Le texte complet de cet article est disponible en PDF.

Keywords : Amyotrophic lateral sclerosis, F-waves, Hand muscles, Motor units, Split-hand


Plan


© 2024  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 54 - N° 6

Article 103018- novembre 2024 Retour au numéro
Article précédent Article précédent
  • Anatomical measurements and field modeling to assess transcranial magnetic stimulation motor and non-motor effects
  • Francis Houde, Russell Butler, Etienne St-Onge, Marylie Martel, Véronique Thivierge, Maxime Descoteaux, Kevin Whittingstall, Guillaume Leonard
| Article suivant Article suivant
  • Transcranial MEPs predict clinical outcome during minimally invasive dorsal decompression for cervical spondylotic myelopathy
  • Fares Komboz, Fabian Kück, Silvia Hernández-Durán, Ingo Fiss, Xenia Hautmann, Dorothee Mielke, Veit Rohde, Tammam Abboud

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.