S'abonner

Quoi de neuf sur les prothèses métatarsophalangiennes du 1er rayon (MtP1) ? - 25/10/24

What's new in metatarsophalangeal prostheses (MtP1)?

Doi : 10.1016/j.rcot.2024.07.027 
Michel Maestro 1, , Solenne Frey-Ollivier 2, Martin Schramm 1
1 Institut monégasque de médecine du sport (IM2S), Monaco 
2 Centre du pied 13, Marseille, La Ciotat, France 

Michel Maestro, Institut monégasque de médecine du sport (IM2S), 11, avenue d’Ostende, 98000 Monaco.Institut monégasque de médecine du sport (IM2S)11, avenue d’Ostende98000Monaco

Résumé

Les prothèses MtP1 sont généralement proposées devant des lésions irréparables ou non conservables comme alternative à l’arthrodèse. Toutes les prothèses bi- et tricomposants avec matériaux métalliques et polyéthylène devraient être abandonnées en raison de l’usure inéluctable des matériaux utilisés générant des réactions à corps étrangers responsables d’ostéolyse secondaire. L’insuffisance iatrogénique anatomique du premier rayon ainsi engendrée va se compliquer avec risque de déstructuration des rayons latéraux (un seul implant tricomposant à double mobilité a passé avec succès la barre des 10 an). Leur révision par arthrodèse-reconstruction est difficile, leur fusion plus lente, les complications sont plus fréquentes et les résultats fonctionnels moins bons que les arthrodèses de première intention. Les recherches dans le domaine des arthroplasties continuent, car préserver la mobilité de la MtP1 est souhaitable. La MtP1 n’est pas une simple énarthrose et élaborer une arthroplastie prothétique sur ce concept conduira inévitablement à l’erreur. À côté des arthroplasties totales il y a le vaste champ d’investigation des arthroplasties dites d’interposition qui ont l’avantage de ne pas entraîner de destruction osseuse importante mais ont pour inconvénient des résultats aléatoires, leur reprise par arthrodèse est moins problématique. Face à la disparité des résultats pour les arthroplasties faut-il concevoir de nouveaux matériaux ? Certainement oui car l’arthrodèse devrait être réservée comme possibilité de révision si l’on peut raisonnablement proposer une conservation de mobilité avec une force efficace. Il en existe actuellement trois qui sont les suivants : – le Gelfoam peu onéreux peu diffusé ; – le cartilage artificiel synthétique présente des taux non négligeables de complications, il n’est pas autorisé en France ; – les implants en pyrocarbone fonctionnent bien en interposition, parfaitement biocompatibles et ne détruisant pas l’os, ils ont peu été diffusés car initialement utilisés sur un mauvais concept cherchant l’ostéointégration impossible avec ce matériau prometteur. Ils ne seront plus disponibles par arrêt de production en 2024 !

Niveau de preuve

V, avis d’expert.

Le texte complet de cet article est disponible en PDF.

Summary

MtP1 prostheses are generally proposed for irreparable or non-conservable lesions as an alternative to arthrodesis. All two- and three-component prostheses using metal and polyethylene materials should be abandoned, as the materials used inevitably wear out, generating foreign-body reactions responsible for secondary osteolysis. The resulting iatrogenic anatomical insufficiency of the first radius will be complicated by the risk of destructuring the lateral radii (only one tri-component dual mobility implant has successfully passed the 10-year mark). Revision by reconstruction arthrodesis is difficult, fusion is slower, complications are more frequent and functional results are poorer than with first-line arthrodesis. Research in the field of arthroplasty continues, as preserving the mobility of MtP1 is desirable. MtP1 is not a simple enarthrosis, and designing a prosthetic arthroplasty around this concept will inevitably lead to error. Alongside total arthroplasties, there is the vast field of investigation of so-called interposition arthroplasties, which have the advantage of not leading to significant bone destruction, but have the disadvantage of random results, their revision by arthrodesis being less problematic. Given the disparity in arthroplasty results, should new materials be developed? Certainly, because arthrodesis should be reserved as a revision option if it can be reasonably proposed to preserve mobility with effective force. Three such materials are currently available: - Gelfoam, which is inexpensive and not widely available; - synthetic artificial cartilage is not authorized in France, as it has a high complication rate; - pyrocarbon implants work well in interposition, are perfectly biocompatible and do not destroy bone. They have not been widely used, however, as they were initially based on a poor concept that sought osseointegration, which was impossible with this promising material. They will be discontinued in 2024!

Level of evidence

V; expert opinion.

Le texte complet de cet article est disponible en PDF.

Mots clés : Arthroplasties métatarso phalangiennes du premier rayon, Prothèses MtP1, Arthrodèse MtP1

Keywords : Metatarsophalangeal arthroplasties of the phalangeal arthroplasties, MtP1 prostheses, MtP1 arthrodesis


Plan


 Cet article reprend le chapitre correspondant du livre « L’Avant-pied en 15 Questions » de Didier Mainard et Carlos Maynou publié en novembre 2022, pour en élargir la diffusion auprès des lecteurs de la RCOT. Avec les remerciements de la Rédaction aux Auteurs.


© 2024  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 110 - N° 7

P. 1026-1039 - novembre 2024 Retour au numéro
Article précédent Article précédent
  • Les nouvelles techniques d’imagerie fonctionnelle modifient-elles nos indications thérapeutiques ?
  • François Lintz, Julien Beldame, Gérard Morvan
| Article suivant Article suivant
  • Quel algorithme décisionnel pour l’arthrose métatarsophalangienne de l’hallux ?
  • Véronique Darcel, Alexis Thiounn

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.