S'abonner

Influence de la luminosité de l’écran sur la lecture chez des personnes atteintes du syndrome de l’œil sec - 11/09/24

Influence of screen brightness on reading in dry eye patients

Doi : 10.1016/j.jfo.2024.104290 
A. Zenouda a, , S. Ajasse a, M. Lombardi a, J.-A. Sahel b, c, H. Liang b, C. Baudouin b, c, d
a Streetlab, Vision Institute, IHU FOReSIGHT, 75012 Paris, France 
b IHU FOReSIGHT, Inserm-DHOS CIC 1423, Quinze-Vingts National Ophthalmology Hospital, Paris, France 
c Inserm, U968, UMR_S968, Institut de la Vision, CNRS, UMR 7210, CHNO des Quinze-Vingts, Inserm-DHOS CIC 503, UPMC University of Paris 06, Paris, France 
d Department of Ophthalmology, Ambroise-Paré Hospital, AP–HP, University of Versailles Saint-Quentin-en-Yvelines, Versailles, France 

Auteur correspondant.

Résumé

But

Cette étude examine l’impact de la sécheresse oculaire sur la lecture sur écran, en mettant l’accent sur l’éblouissement et le confort visuel des patients.

Population et méthodes

Nous avons recruté dix patients atteints de sécheresse oculaire et neuf témoins sains. Une évaluation ophtalmologique a été effectuée pour caractériser les signes cliniques de la sécheresse oculaire tels que les propriétés du film lacrymal et la topographie cornéenne. Des questionnaires relatifs à la qualité de vie et à la sensibilité lumineuse ont été administrés. Tous les participants ont été soumis à une épreuve de lecture sur écran sous cinq niveaux de luminosité différents.

Résultats

Les patients atteints de sécheresse oculaire présentaient une inflammation oculaire plus importante (score d’Oxford), un temps de rupture lacrymal réduit (BUT ; DED : 4,1s, CO : 11,8s ; W=90, p<0,001) par rapport à la population contrôle. Les patients présentaient également une qualité de vie altérée (score OSDI : CO : 15,044±9,16, DED : 38,150±18,66, p=0,004) et une sensibilité lumineuse accrue (Glare test : CO : 96,56±65,5 arc.min, DED : 204,1±82,5 arc.min, W=15, p=0,013 ; VLSQ score : CO : 16,44±4,85, DED : 22,0±6,34, p=0,049). Les tests de lecture n’ont pas montré de différence significative entre les groupes (CO : 155±23,3 mots/min et DED : 149±28,0, F=1,935, p=0,169). La luminosité n’a pas influencé la vitesse de lecture (F=1,308, p-value=0,275). Une corrélation a été observée entre la vitesse de lecture et le questionnaire de qualité de vie OSDI (R=−0,7, p=0,043).

Conclusion

Bien que la luminosité de l’écran n’ait pas eu d’impact notable sur la vitesse de lecture, l’éblouissement s’est avéré être un enjeu majeur pour les patients atteints de sécheresse oculaire. Les associations entre les manifestations cliniques de la sécheresse et les performances de lecture mettent en avant l’importance d’une prise en charge globale de cette affection. Les résultats suggèrent que la sécheresse oculaire peut influencer la qualité de vie et la lecture sur écran, impliquant un besoin d’approches dédiées pour améliorer le confort visuel des patients.

Le texte complet de cet article est disponible en PDF.

Summary

Purpose

This study examines the impact of dry eye on screen reading, with an emphasis on glare and visual comfort for patients.

Population and methods

We recruited ten patients with dry eye and nine healthy controls. Clinical signs of dry eye were quantified to determine the quality of the tear film and corneal aberrations. Questionnaires related to quality of life and light sensitivity were administered. All participants underwent a screen reading test under five different levels of brightness.

Results

Patients with dry eye presented with more significant ocular inflammation (Oxford score) and reduced tear breakup time (BUT; DED: 4.1s, CO: 11.8s; W=90, P<0.001) compared to the control population. Patients also exhibited impaired quality of life (OSDI score: CO: 15.044±9.16, DED: 38.150±18.66, P=0.004) and increased light sensitivity (Glare test: CO: 96.56±65.5 arc.min, DED: 204.1±82.5 arc.min, W=15, P=0.013; VLSQ score: CO: 16.44±4.85, DED: 22.0±6.34, P=0.049). Reading tests did not show a significant difference between the groups (CO: 155±23.3 words/min and DED: 149±28.0, F=1.935, P=0.169). Brightness did not influence reading speed (F=1.308, P-value=0.275). A correlation was observed between reading speed and the OSDI quality of life questionnaire (R=−0.7, P=0.043).

Conclusion

Although screen brightness did not have a significant impact on reading speed, glare proved to be a major issue for patients with dry eye. The associations between clinical manifestations of dry eye and reading performance emphasize the importance of comprehensive management of this condition. The results suggest that dry eye can influence both quality of life and screen reading, highlighting the need for dedicated approaches to improve the visual comfort of patients.

Le texte complet de cet article est disponible en PDF.

Mots clés : Syndrome de la vision liée à l’ordinateur, Sécheresse oculaire, Lecture, Éblouissement

Keywords : Computer vision syndrome, Dry eye disease, Reading, Glare


Plan


© 2024  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 47 - N° 9

Article 104290- novembre 2024 Retour au numéro
Article précédent Article précédent
  • Pterygium recurrence following preoperative topical Mitomycin C and 5-Fluorouracil eyedrops
  • J. Rajagopal, G.K. Das, S. Sharma, P.K. Sahu
| Article suivant Article suivant
  • Unveiling a distinctive presentation: Benign manifestation of primary ductal adenocarcinoma of the lacrimal gland
  • C. Luo, J. Chen, Z. Wang, D. Fu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.