S'abonner

Impact of the nail insertion angle on the wedge effect in intramedullary nail fixation of intertrochanteric hip fractures - 11/09/24

Doi : 10.1016/j.otsr.2024.103989 
Wenhui Zhang, Ping Chen, Ji Qi, Zhirong Fan, Xiubing Yu, Haizhou Wang
 Guangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou University of Chinese Medicine, 510006 Guangzhou, China 

Corresponding author.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Wednesday 11 September 2024

Abstract

Background

The wedge effect is known to be influenced by the insertion of the proximal femoral intramedullary nail through the fracture line and the large proximal diameter of the nail. However, the impact of the nail insertion angle (NIA) on the wedge effect remains unclear. This study aimed to investigate: (1) how to evaluate the NIA intraoperatively, (2) whether the NIA is associated with the wedge effect, (3) whether the NIA can serve as a reliable predictor of the wedge effect, (4) which factors affect the NIA, and (5) which surgical techniques can prevent the occurrence of the wedge effect associated with the NIA.

Hypothesis

We hypothesized that an excessive NIA is related to the wedge effect and that lateral deviation of the entry point is associated with an excessive NIA.

Patients and methods

Intraoperative fluoroscopy images of patients who underwent intramedullary nail fixation for intertrochanteric hip fractures between 2013 and 2023 were analyzed. NIA and insertion point distance (IPD) were measured on hip anteroposterior radiographs with the guidewire inserted. Femoral shaft lateralization (FSL) and neck-shaft angle (NSA) were measured on hip anteroposterior radiographs before and after nail insertion; differences in FSL and NSA were calculated. A negative difference in FSL combined with a positive difference in NSA indicated the occurrence of the wedge effect. Pearson’s correlation test was used to determine relationships between continuous variables (NIA, FSL, NSA, and IPD). Binary logistic regression analyzed the association between NIA and the wedge effect. Receiver operating characteristic (ROC) curve analysis was used to determine the threshold value of NIA, with predictive performance assessed using the area under the ROC curve (AUC). Other potential factors influencing the wedge effect were also examined.

Results

A total of 408 patients were included. The mean NIA was 15.61 ± 4.49 °. Post-nail insertion, the average increase in FSL was 3.20 mm, and the average decrease in NSA was 1.90 °. Pearson’s correlation test revealed that NIA was negatively correlated with the difference in FSL (R = 0.565, P < 0.001) and positively correlated with the difference in NSA (R = 0.509, P < 0.001). Binary logistic regression showed a significant correlation between NIA and the wedge effect (P < 0.001). ROC analysis indicated that the AUC for NIA was 0.813, with an optimal cutoff point of 14.85 °. IPD was positively correlated with NIA (R = 0.519, P < 0.001). Unstable fractures were associated with increased lateralization of the femoral shaft after nail insertion (P = 0.003).

Discussion

The NIA is positively correlated with the wedge effect in intramedullary nail fixation of intertrochanteric hip fractures. The wedge effect tends to occur when the NIA is >14.85 °, particularly in unstable fractures. Lateral deviation of the entry point is associated with an excessive NIA. Adducting the affected limb, moving the entry point slightly medial and using a medial pusher may help control the NIA to less than 14.85 ° to reduce the wedge effect.

Level of evidence

III.

Le texte complet de cet article est disponible en PDF.

Keywords : Intertrochanteric hip fractures, Proximal femur nail antirotation, Wedge effect, Nail insertion angle, Nail insertion point


Plan


© 2024  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.