S'abonner

Deviation parameters of intraoral scanning with and without artificial markers versus conventional impression of total, partial and congenital nasal defects: A pilot non-randomized clinical trial - 11/09/24

Doi : 10.1016/j.jormas.2024.102049 
Mohamed Amr ElKhashab a, Fatma ElMougi b, Iman AbdelWahab Radi c,
a Lecturer of prosthodontics, Faculty of Dentistry, Cairo University, Cairo, Egypt 
b Assistant Lecturer of Prosthodontics, Faculty of Dentistry, New Giza University, Giza, Egypt 
c Professor of Prosthodontics, Member of Evidence Based Dentistry Center, Faculty of Dentistry, Cairo University, Cairo, Egypt 

Corresponding author: Faculty of Dentistry, Cairo University. 11 ElSaraya St, EL Manial 11553, Cairo, Egypt.Faculty of DentistryCairo University.11 ElSaraya St, EL ManialCairo11553Egypt
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Wednesday 11 September 2024

Abstract

Purpose

This pilot clinical trial aimed to investigate accuracy of intra-oral scanning (IOS) with and without artificial reference markers in capturing total, subtotal and congenital nasal defects.

Basic procedures

Thirteen patients with 3 types of nasal defects were selected and digitally scanned using an IOS with (ScM) and without artificial markers (Sc). Patients were grouped as follows; Group T (total nasal defect), Group P (partial/subtotal nasal defect), Group C (congenital defect). Silicone impressions of the defects were made and poured to get a model that was scanned using a Desktop scanner (Imp). The standard tessellation language (STL) files obtained from IOS were registered and compared to each other using a processing software. RMS, positive and negative average values were used to report deviations between the scans. Kruskal Wallis test was used to study the effect of defect type, while Friedmann was used to study the effect of impression technique. Results were considered significant at P≤.05.

Main findings

All deviation values showed statistically significant differences among the 3 studied nasal defects and among the 3 investigated impression techniques. The smallest deviation values were recorded in Sc-ScM of congenital defects (RMS= 0.13±0.04, +average=0.08±0.01, -average=-0.09±0.02), while the largest deviation values were recorded in IMP-Sc in the total defects (RMS= 0.38±0.05, +average=0.29±0.04, -average=-0.29±0.04).

Conclusions

Within the limitations of this study, it was concluded that the nasal defect type and the use of artificial markers during scanning affect the deviation parameters of the obtained scan. The combined effect of the studied parameters calls for the use of markers in when scanning total nasal defects.

Le texte complet de cet article est disponible en PDF.

Keywords : Intraoral scanner, IOS, Artificial markers, Nasal defects, Facial scan, Deviation


Plan


© 2024  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.