S'abonner

Feasibility of Ultrasound-based Measurement of the Intra-scaphoid Using a Three-point Measurement Technique - 06/08/24

Doi : 10.1016/j.hansur.2024.101755 
Mauro Maniglio a, b, , Bérénice Moutinot c, b , Sébastien Durand b
a Department of Hand Surgery, Balgrist University Clinic, Zürich, Switzerland 
b Department of Hand and Plastic Surgery, CHUV Centre Hospitalier Universitaire Vaudois, University Hospital, Lausanne, Switzerland 
c Department of Hand Surgery, HUG Hôpitaux Universitaires de Genève, Geneva, Switzerland 

Corresponding author
Sous presse. Manuscrit accepté. Disponible en ligne depuis le Tuesday 06 August 2024

Highlights

We described the inter-poles distance (IPD) and the palmar cortical intra-scaphoid angle (PCISA), as two sonographic measurements of the scaphoid alignment.
This technique is easy to perform, is cost-effective, accessible and radiation-free.
There is moderate to good correlation for PCISA and good to excellent correlation for IPD between the investigators.
There is a fair to moderate correlation for IPD and moderate to good correlation for PCISA in between evaluators.

Le texte complet de cet article est disponible en PDF.

Abstract

Introduction

Ultrasound is gaining popularity for diagnosing scaphoid fractures. However, it hasn't been used to assess fracture displacement, such as humpback deformity. We propose a sonographic method to measure the intra-scaphoid angle, potentially serving as an alternative to CT scans for detecting fragment malposition after a scaphoid fracture.

Methods

We recruited 11 healthy adult volunteers without wrist pathology and performed bilateral wrist ultrasounds, totaling 22 examinations. Each wrist was splinted at 50 ° extension and fully supinated. Two hand surgeons independently performed the ultrasounds. All images were then evaluated separately by two evaluators.

The following measurements were taken:

Inter-poles distance (IPD): Distance between the summits of the two scaphoid poles on the palmar cortex.

Palmar cortical intra-scaphoid angle (PCISA): Angle between the two summits and the deepest point of the waist on the palmar cortex.

Measurements were compared for inter-investigator and inter-evaluator reliability using the intraclass correlation coefficient (ICC).

Results

The study included four males and seven females, with an average age of 35 years (range 21-56). The mean PCISA was 142 ° (SD 10 °) and the mean IPD was 16.3 mm (SD 2.1 mm). Differences in IPD measurements averaged 0.3 mm (range 0 to 5.2 mm) among investigators and 1.0 mm (range 0.1 to 3.8 mm) among evaluators. For PCISA, the differences averaged 4 ° (range 0 to 17 °) among investigators and 6 ° (range 0 to 15 °) among evaluators. The ICC for IPD was 0.804 (investigators) and 0.572 (evaluators); for PCISA, it was 0.704 (investigators) and 0.602 (evaluators).

Conclusion

This study presents a cost-effective and accessible sonographic technique to measure the intra-scaphoid angle. Further research is required to assess its effectiveness in scaphoid fractures and compare it to CT-based measurements like the H/L ratio, LISA, and DCA.

Le texte complet de cet article est disponible en PDF.

Keywords : Sonographic measurement, Ultrasound, Scaphoid fracture, Scaphoid, Scaphoid non-union, Humpback deformity, Diagnostic accuracy



© 2024  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.