Evaluation of a pilot regional neurotrauma workshop using 3D printed simulation models - 01/08/24

Doi : 10.1016/j.stlm.2024.100169 
Nalinda Dissanayaka a, b, c, , Hamish Alexander b, d, e, Michael Redmond b, d, e, f, Patrick Pearce d, e, Andrew Hobbins-King g, Kate Lee h, Danilo Carluccio b, i, j, Roozbeh Fakhr b, k, Luigi-Jules Vandi c, l, James I. Novak b, m
a School of Chemical Engineering, Faculty of Engineering, Architecture and Information Technology, The University of Queensland, Brisbane, Australia 
b Herston Biofabrication Institute, Metro North Hospital and Health Service, Brisbane, Australia 
c Centre for Advanced Materials Processing and Manufacturing (AMPAM), The University of Queensland, Brisbane, Australia 
d Kenneth G Jamieson Department of Neurosurgery, Royal Brisbane and Women's Hospital, Brisbane, Australia 
e Faculty of Medicine, The University of Queensland, Brisbane, Australia 
f College of Medicine and Public Health, Flinders University, Australia 
g Trauma Department, Sunshine Coast Hospital and Health Service, Birtinya, Australia 
h Medtronic Australasia Pty Ltd, Bowen Hills, Australia 
i School of Dentistry, Faculty of Health and Behavioural Sciences, The University of Queensland, Brisbane, Australia 
j Oral and Maxillofacial Surgery Department, Royal Brisbane and Women's Hospital, Brisbane, Australia 
k School of Design, Faculty of Creative Industries, Education and Social Justice, Queensland University of Technology, Kelvin Grove, Australia 
l School of Mechanical and Mining Engineering, Faculty of Engineering, Architecture and Information Technology, The University of Queensland, Brisbane, Australia 
m School of Architecture, Design and Planning, Faculty of Engineering, Architecture and Information Technology, The University of Queensland, Brisbane, Australia 

Corresponding author at: The School of Chemical Engineering, Andrew N. Liveris, Building 46, Staff House Rd, St Lucia QLD 4067, Australia.The School of Chemical EngineeringAndrew N. Liveris, Building 46, Staff House RdSt Lucia QLD4067Australia

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Objective

Non-neurosurgeons in regional and rural hospitals may be required to operate on patients presenting with a traumatic brain injury where timely transfer to a tertiary hospital is not possible. Confidence and experience can vary significantly due to limited access to hands-on training. Increasing availability to advanced 3D printed models opens new opportunities to provide accurate head models suitable for this purpose. This study evaluated the experience of regional clinicians and nurses following a neurotrauma workshop where 3D printed head models were used to provide training in burr hole and craniotomy procedures.

Methods

A neurotrauma seminar and workshop was hosted at the Sunshine Coast Health Institute, in the state of Queensland, Australia. The workshop component allowed 26 local clinicians and nurses to gain hands-on experience with a 3D printed head model, guided by neurosurgeons from the closest tertiary hospital. Following training, participants completed a short survey.

Results

Prior to this workshop, most participants had never performed a burr hole (58 %, n=15) or interacted with a 3D printed model (69 %, n=18). Overall, most participants indicated that the 3D printed model performed better (58 %, n=15) and much better (15 %, n=4) than their expectations. 81 % (n=21) left the workshop with improved confidence in performing burr hole and craniotomy procedures. Despite some melting of the plastic, 96 % (n=25) of participants would recommend this model to their colleagues.

Le texte complet de cet article est disponible en PDF.

Keywords : Additive manufacturing, Anatomical models, Burr hole, Craniotomy, Medical training, Neurosurgery, Rural medicine, Traumatic brain injury


Plan


© 2024  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 15

Article 100169- août 2024 Retour au numéro
Article précédent Article précédent
  • 3D surgical planning method for lower jaw osteotomies applied to facial feminization surgery
  • Valeria Marin-Montealegre, Amelia R. Cardinali, Valentina Ríos Borras, M. Camila Ceballos-Santa, Jhon Jairo Osorio-Orozco, Iris V. Rivero
| Article suivant Article suivant
  • An automatic procedure for modelling patient-specific wrist orthosis
  • Michaela Servi, Roberto Magherini, Yary Volpe, Rocco Furferi

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.