S'abonner

Gonioscopy-Assisted Transluminal Trabeculotomy Outcomes Under Different Levels of Glaucoma Severity: A Multicenter, Comparative Study - 17/07/24

Doi : 10.1016/j.ajo.2024.02.033 
Leopoldo Magacho 1, 2, , Cláudia Gomide Vilela de S. Franco 1, Eduardo Akio I 1, Ana Cláudia Alves Pereira 3, 4, Bruno Teno 5, Francisco Lucena-Neto 5, Bruno M. Faria 6, 7, Júlia Maggi Vieira 8, Marcos Pereira Vianello 9, Fábio N. Kanadani 8, 9, 10
1 From the Department of Ophthalmology, Federal University of Goiás (CEROF-UFG) (L.M., C.G.V.d.S.F., E.A.I.), Goiânia, Goiás, Brazil 
2 VER Hospital (L.M.), Goiânia, Goiás, Brazil 
3 Department of Ophthalmology, Federal University of Mato Grosso do Sul (A.C.A.P.), Campo Grande, Mato Grosso do Sul, Brazil 
4 Eye Hospital of Mato Grosso do Sul (A.C.A.P.), Campo Grande, Mato Grosso do Sul, Brazil 
5 D'Olhos Day Hospital, São José do Rio Preto (B.T., F.L.-N.), São Paulo, Brazil 
6 Marco Rey Ophthalmology Institute (B.M.F.), Natal, Rio Grande do Norte, Brazil 
7 Department of Ophthalmology, Federal University of Rio Grande do Norte (B.M.F.), Natal, Rio Grande do Norte, Brazil 
8 Glaucoma Institute (J.M.V., F.N.K.), Belo Horizonte, Minas Gerais, Brazil 
9 Department of Ophthalmology, Federal University of São Paulo, São Paulo (M.P.V., F.N.K.), São Paulo, Brazil 
10 Department of Ophthalmology, Mayo Clinic (F.N.K.), Jacksonville, Florida, USA 

Inquiries to Leopoldo Magacho, VER Hospital, Goiânia, Goiás, BrazilVER HospitalGoiâniaGoiásBrazil

Résumé

PURPOSE

To evaluate the outcomes of gonioscopy-assisted transluminal trabeculotomy (GATT) under different levels of glaucoma severity.

DESIGN

Retrospective, multicenter, before-and-after study.

METHODS

One eye from all primary open-angle glaucoma patients who underwent GATT combined with cataract surgery (Phaco-GATT) or GATT stand-alone with 12 months of follow-up were included and divided according to glaucoma severity (mild = GI, moderate = GII, and advanced = GIII) and the outcomes compared.

RESULTS

A total of 270 eyes were included: 90 in GI, 75 in GII, and 105 in GIII. The IOP was reduced from 18.6 ± 6.0 mm Hg in GI, 19.7 ± 6.4 mm Hg in GII, and 21.0 ± 7.9 mm Hg in GIII, preoperatively, to 11.9 ± 2.6 mm Hg in GI, 11.8 ± 2.1 mm Hg in GII, and 11.9 ± 3.0 mm Hg in GIII at 12 months postoperatively (P < .001 for all). The number of hypotensive ocular medications were reduced from 2.7 ± 1.0 in GI, 3.1 ± 0.8 in GII, and 3.2 ± 1.2 in GIII to 0.6 ± 0.9 in GI, 1.0 ± 1.1 in GII, and 1.2 ± 1.1 in GIII at the last postoperative visit (P < .001 for all). Relative success was achieved, at 1 year, in 93.8% of the eyes in GI, 89.0% in GII, and 88.1% in GIII (P = .3). Complete success was achieved in 61.8% of the eyes in GI, 43.8% in GII, and 37.6% in GIII (P = .007). No serious adverse event was observed in any group.

CONCLUSIONS

GATT is a safe and effective procedure in glaucoma, regardless of its preoperative severity.

Le texte complet de cet article est disponible en PDF.

Plan


© 2024  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 264

P. 75-84 - août 2024 Retour au numéro
Article précédent Article précédent
  • A Randomized, Controlled Comparison of NCX 470, a Nitric Oxide-Donating Bimatoprost, and Latanoprost in Subjects with Open-Angle Glaucoma or Ocular Hypertension: The MONT BLANC Study
  • Robert Fechtner, Steven Mansberger, James Branch, Jay Mulaney, Sara Ziebell, Krisi Lopez, Doug Hubatsch
| Article suivant Article suivant
  • Association of Ocular Manifestations of Marfan Syndrome With Cardiovascular Complications
  • Elaine M. Tran, Karen M. Wai, Andrea L. Kossler, Prithvi Mruthyunjaya, Ehsan Rahimy, Euna B. Koo

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.