S'abonner

En Face and Volumetric Comparison of Hypertransmission Defects Evaluated by Cirrus and Spectralis Optical Coherence Tomography - 17/07/24

Doi : 10.1016/j.ajo.2024.03.003 
Jiwon Baek 1, 2, 3, 4, Maryam Ashrafkhorasani 1, Alireza Mahmoudi 1, 4, Muneeswar Gupta Nittala 1, Giulia Corradetti 1, 4, SriniVas R. Sadda 1, 4,
1 From the Doheny Eye Institute (J.B., M.A., A.M., M.G.N., G.C., S.R.S.), Pasadena, California, USA 
2 Department of Ophthalmology, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea (J.B.), Bucheon, Gyeonggi-do, South Korea 
3 Department of Ophthalmology, College of Medicine, The Catholic University of Korea (J.B.), Seoul, South Korea 
4 Department of Ophthalmology, David Geffen School of Medicine at UCLA (J.B., A.M., G.C., S.R.S.), Los Angeles, California, USA. 

Inquiries to SriniVas R. Sadda, MD, Doheny Eye Institute, Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, California, USADoheny Eye InstituteDepartment of Ophthalmology, David Geffen School of Medicine at UCLALos AngelesCaliforniaUSA

Résumé

Purpose

To evaluate and compare en face and 3-dimensional (3-D) properties of hypertransmission defects (HTDs) between different optical coherence tomography (OCT) devices using OCT volumes and reconstructed en face images.

Settings

Comparative diagnostic evaluation study.

Methods

Thirty eyes with dry age-related macular degeneration (AMD) that underwent dense OCT macular volume scans with both the Spectralis (97 B-scans/volume; 2910 B-scans in total) and Cirrus OCT (128 B-scans/volume; 3840 B-scans in total) from the Amish Eye Study cohort were included in this analysis. HTD regions were labeled on each B-scan and reconstructed into en face and 3-D volume images. Properties of HTD volume were compared between the 2 devices.

Results

The qualitative score of en face images for HTD was higher for the Cirrus compared to the Spectralis (P < .01). The quality of Spectralis en face images improved after preprocessing and reconstruction. The 2-D HTD area on en face obtained from 2-D projections of 3-D volume did not differ between devices (P = .478, ICC = 0.998; Jaccard index 0.721 ± 0.086). There was no difference in the number, volume, PALs, and surface areas of HTDs between devices in the volumetric analysis (all P ≥ .090). The signal intensity of HTD normalized by the mean choroidal signal intensity did not differ between devices (P = .861).

Conclusions

The visualization of HTD on en face images from Spectralis OCT could be enhanced through image processing. The equivalence in 3-D HTD parameters between the 2 devices suggests interchangeability for assessing these lesions in AMD.

Le texte complet de cet article est disponible en PDF.

Plan


 Supplemental Material available at AJO.com.


© 2024  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 264

P. 135-144 - août 2024 Retour au numéro
Article précédent Article précédent
  • Peripheral Vision in Patients Following Intraocular Lens Implantation: A Systematic Review and Meta-Analysis
  • Pablo Artal, Maria Arvaniti, Panaghiota Dimou, Costas Stavrinos, Harilaos Ginis, Lucía Hervella, José Luis Güell
| Article suivant Article suivant
  • Correlation of Refractive Error with Anisometropia Development in Early Childhood
  • Michael Kinori, Itay Nitzan, Naava Sadi Szyper, Asaf Achiron, Oriel Spierer

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.