S'abonner

Anatomical Annulus Predictors of New Permanent Pacemaker Implantation Risk After Balloon-Expandable Transcatheter Aortic Valve Implantation - 16/07/24

Doi : 10.1016/j.amjcard.2024.05.034 
Francesco Bianchini, MD a, Emiliano Bianchini, MD a, Enrico Romagnoli, MD, PhD a, b, , Cristina Aurigemma, MD, PhD a, b, Andrea Zito, MD a, Marco Busco, MD a, Marialisa Nesta, MD, PhD a, b, Piergiorgio Bruno, MD, PhD a, b, Domenico Laezza, BS b, Nicole Giambusso, BS b, Luigi Natale, MD, PhD a, b, Gemma Pelargonio, MD, PhD a, b, Francesco Burzotta, MD, PhD a, b, Carlo Trani, MD a, b
a Department of Cardiovascular and Pulmonary Sciences, Università Cattolica del Sacro Cuore, Rome, Italy 
b Department of Cardiovascular Sciences, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy 

Corresponding author: Tel: +39 0630156622.

Résumé

New-generation transcatheter heart valves have significantly improved technical success and procedural safety of transcatheter aortic valve implantation (TAVI) procedures; however, the incidence of permanent pacemaker implantation (PPI) remains a concern. This study aimed to assess the role of anatomic annulus features in determining periprocedural conduction disturbances leading to new PPI after TAVI using the last-generation Edwards SAPIEN balloon-expandable valves. In the context of a prospective single-center registry, we integrated the clinical and procedural predictors of PPI with anatomic data derived from multislice computed tomography. A total of 210 consecutive patients treated with balloon-expandable Edwards transcatheter heart valve were included in the study from 2015 to 2023. Technical success was achieved in 197 procedures (93.8%), and 26 patients (12.4%) required new PPI at the 30-day follow-up (median time to implantation 3 days). At the univariable logistic regression analysis, preprocedural right bundle branch block (odds ratio [OR] 2.24, 95% confidence interval [CI] 1.01 to 4.97, p = 0.047), annulus eccentricity ≥0.25 (OR 5.43, 95% CI 2.21 to 13.36, p <0.001), calcium volume at annulus of the right coronary cusp >48 mm3 (OR 2.60, 95% CI 1.13 to 5.96, p = 0.024), and prosthesis implantation depth greater than membranous septum length (OR 2.17, 95% CI 1.10 to 4.28, p = 0.026) were associated with new PPI risk. In the multivariable analysis, preprocedural right bundle branch block (OR 2.81, 95% CI 1.01 to 7.85, p = 0.049), annulus eccentricity ≥0.25 (OR 4.14, 95% CI 1.85 to 9.27, p <0.001), and annulusright coronary cusp calcium >48 mm3 (OR 2.89, 95% CI 1.07 to 7.82, p = 0.037) were confirmed as independent predictors of new PPI. In conclusion, specific anatomic features of the aortic valve annulus might have an additive role in determining the occurrence of conduction disturbances in patients who underwent TAVI with balloon-expandable valves. This suggests the possibility to use multislice computed tomography to improve the prediction of post-TAVI new PPI risk.

Le texte complet de cet article est disponible en PDF.

Graphical Abstract




Image, graphical abstract

Le texte complet de cet article est disponible en PDF.

Keywords : annulus eccentricity, calcium load, permanent pacemaker implantation, SAPIEN, transcatheter aortic valve implantation


Plan


 Dr. Francesco Bianchini and Dr. Emiliano Bianchini are the co-principal investigators and should be considered co-first authors.
 Funding: none.


© 2024  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 224

P. 26-35 - août 2024 Retour au numéro
Article précédent Article précédent
  • Atherosclerotic Coronary Plaque Features in Patients With Chronic Obstructive Pulmonary Disease and Acute Coronary Syndrome
  • Michele Russo, Massimiliano Camilli, Giulia La Vecchia, Riccardo Rinaldi, Alice Bonanni, Matteo Pio Natale, Carmine Salzillo, Ilaria Torre, Carlo Trani, Filippo Crea, Rocco A. Montone
| Article suivant Article suivant
  • Two-Year Clinical Outcomes of Staged Transcatheter Mitral Edge-to-Edge Repair After Transcatheter Aortic Valve Replacement
  • Takashi Nagasaka, Alon Shechter, Vivek Patel, Ofir Koren, Tarun Chakravarty, Wen Cheng, Hideki Ishii, Hasan Jilaihawi, Mamoo Nakamura, Raj R. Makkar

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.