S'abonner

Effects of the use of a cocoon on the autonomic, motor, and regulatory systems in preterm newborns: Randomized clinical trial - 16/05/24

Doi : 10.1016/j.arcped.2024.01.005 
Anni Lima Ribeiro a, Mayara Fabiana Pereira Costa a, Pedro Ykaro Fialho Silva a, Rayane Oliveira Lima a, Ruth Batista Bezerra a, Ingrid Fonsêca Damasceno Bezerra a, Vanessa Braga Torres a, Carolina Daniel de Lima Alvarez b, Ingrid Guerra Azevedo c, Silvana Alves Pereira b,
a Januário Cicco Maternity School, Federal University of Rio Grande do Norte, UFRN, Natal, Rio Grande do Norte, Brazil 
b Department of Physical Therapy, Federal University of Rio Grande do Norte, UFRN, Natal, Rio Grande do Norte, Brazil 
c Academic Vicerectory, Catholic University of Temuco, Rudecindo Ortega 03694, Edificio EDI 2 Piso, Manuel Montt 56, Temuco, La Araucanía, Chile 

Corresponding author at: Federal University of Rio Grande do Norte (UFRN), University Campus, Lagoa Nova, Natal, RN, CEP 59078-970, Brazil.Federal University of Rio Grande do Norte (UFRN)University Campus, Lagoa NovaNatalRNCEP 59078-970Brazil

Abstract

Introduction

The wrapping of the newborn in an orthopedic tubular mesh, simulating a cocoon, can allow the infant to regain the feeling of security and stability experienced in the uterus given that the movement of one of the parts of the body exerts tactile and pressure variation in others.

Objective

We aimed to evaluate the influence of an orthopedic tubular mesh, simulating a cocoon, in therapeutic positioning, on the variables of the autonomous, motor, and regulatory systems of preterm newborns.

Methods

A controlled and randomized clinical trial was conducted with preterm newborns positioned in dorsal decubitus and divided into two groups: (a) cocoon – newborns covered with an orthopedic tubular mesh, and (b) control – newborns positioned according to the sector's routine and without the use of an orthopedic mesh. During the follow-up, each newborn was placed in the position for 30 min and was recorded for a total of 2 min, once at the beginning and again at the end of the observation period. Variables related to the autonomous system (heart rate, respiratory rate, and peripheral oxygen saturation), motor system (general movements), and regulatory system (Neonatal Infant Pain Scale) were evaluated before and after the intervention. The videos were evaluated by a researcher blind to the purpose of the study, and the resulting data were analyzed using SPSS.

Results

Of the 40 preterm newborns evaluated (32.5 ± 1.83 weeks), 21 were female, and 20 were allocated to the cocoon group. The variables related to the autonomous, motor, and regulatory systems remained unchanged following the positioning in the cocoon, as compared to the typical positioning employed in the neonatal unit.

Conclusion

The simulation of a cocoon, utilizing an orthopedic tubular mesh, when applied to preterm newborns admitted to a neonatal intensive care unit can contribute to maintaining low levels of stress, without altering variables of the autonomous, motor, and regulatory systems.

Le texte complet de cet article est disponible en PDF.

Keywords : Premature newborn, Neonatal intensive care unit, Growth and development, Patient positioning


Plan


 This research did not receive any specific grant from public funding agencies, commercial agencies, or the not-for-profit sector.


© 2024  French Society of Pediatrics. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 31 - N° 4

P. 250-255 - mai 2024 Retour au numéro
Article précédent Article précédent
  • Primary lymphedema of childhood: Treatment results from a tertiary center
  • Ece Cinar, Benil Nesli Ata, Sibel Eyigor
| Article suivant Article suivant
  • Persistent and symptomatic periodic breathing beyond the neonatal period in full-term infants: A case series
  • Océane Cheyrou-Lagrèze, Eglantine Hullo, Jessica Taytard, Lisa Giovannini-Chami, Patricia Franco, Iulia-Cristina Ioan, Laurianne Coutier

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.