S'abonner

Diagnostic and Therapeutic Role of Electrocautery Snare Use in Endobronchial Polypoid Lesions - 24/04/24

Doi : 10.1016/j.resmer.2023.101074 
Banu Kahriman 1, , Celal Satici 1, Sinem Nedime Sokucu 1, Levent Dalar 2, Cengiz Ozdemir 2
1 Yedikule Chest Disease and Chest Surgery Training and Research Hospital, Zeytinburnu, Istanbul, Turkey 
2 Istinye University Faculty of Medicine, Istanbul, Turkey 

Corresponding Author: Banu Kahriman, Department of Chest Diseases, University of Health Sciences Yedikule Chest Disease and Chest Surgery Research and Training Hospital, Istanbul, Turkey.Department of Chest Diseases, University of Health SciencesYedikule Chest Disease and Chest Surgery Research and Training HospitalIstanbulTurkey

Abstract

Introduction

Electrocautery with a snare probe offers a tool for the treatment of endobronchial polyps. The aim of this study was to demonstrate the efficacy of the snare probe in patients undergoing rigid bronchoscopy due to central airway obstruction.

Methods

This retrospective descriptive study included patients who underwent rigid bronchoscopy with an electrocautery snare probe for the diagnosis and/or treatment of endobronchial polyps in an interventional pulmonology unit.

Results

The mean age of the 47 patients (38 men) with endobronchial polypoid lesions was 61.5 years. Six lesions (12.8%) were located in the trachea, 6 (12.8%) in the right main bronchus, 11 (23.4%) in the left main bronchus, and 24 (51.1%) in the lobar bronchi. Twenty-eight lesions (59.5%) were malignant. Prior to the procedure, 6 (12.8%) patients had grade 1 obstruction, 6 (12.8%) had grade 2 obstruction, 15 (31.9%) had grade 3 obstruction, and 20 (42.6%) had grade 4 obstruction. In terms of airway obstruction after the procedure, grade 1 was present in 46 (97.9%) patients and grade 2 was present in 1 (2.1%) patient. No major complication developed in 93.6% of the patients. During a mean follow-up period of 48 months, 85.1% of the patients did not experience recurrence.

Conclusion

Our results demonstrate that the snare probe can be used to effectively and reliably establish airway patency in patients with central airway obstruction due to endobronchial polypoid lesions.

Le texte complet de cet article est disponible en PDF.

Keywords : interventional bronchoscopy, endobronchial therapy, rigid bronchoscopy, central airway obstruction, electrocautery snare probe, polypectomy


Plan


© 2023  SPLF and Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 85

Article 101074- juin 2024 Retour au numéro
Article précédent Article précédent
  • Residual reversibility in COPD patients already on long-acting bronchodilator: The OscilloRevers Study
  • Olivier Le Rouzic, Marjorie Picaud, Hélène Salvator, Nathalie Bautin, Philippe Devillier, Thierry Perez
| Article suivant Article suivant
  • Incidental diagnosis of lung cancer on chest CT scan performed for suspected or documented COVID-19 infection
  • Pascal Wang, Patricia Martel, Mostafa El Hajjam, Lamiae Grimaldi, Etienne Giroux Leprieur, ’AP-HP / Universities / Inserm COVID-19 research collaboration and AP-HP Covid CDW Initiative

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.