S'abonner

Ultrasound image-guided cancer gene therapy using iRGD dual-targeted magnetic cationic microbubbles - 29/02/24

Doi : 10.1016/j.biopha.2024.116221 
Yao Zhu 1, Gulzira Arkin 1, Wei Zeng 1, Yalan Huang, Lili Su, Fengjuan Guo, Jiayu Ye, Guanxi Wen, Jinfeng Xu , Yingying Liu
 Shenzhen Medical Ultrasound Engineering Center, Department of Ultrasonography, Shenzhen People’s Hospital, Second Clinical Medical College of Jinan University, First Clinical Medical College of Southern University of Science and Technology, Shenzhen 518020, China 

Corresponding authors.

Abstract

The gene therapy attracted more and more attention for the tumor therapy. To obtain a safe gene therapy system, the new gene vectors beyond the virus were developed for a high gene therapy efficiency. The ultrasound mediated gene therapy was safer and the plasmid DNA could be delivered by the microbubbles and combined with the ultrasound to increase the gene transfection efficiency. In this work, the cationic microbubbles decorated with Cyclo(Cys-Arg-Gly-Asp-Lys-Gly-Pro-AspCys) (iRGD peptides) and magnetic Fe3O4 nanoparticles (MBiM) was designed for targeted ultrasound contrast imaging guided gene therapy of tumors. The ultrasound image intensity was dramatically enhanced at the tumor site that received MBiM with the magnet applied, compared to those administrated the non-targeted microbubbles (MBb) or the microbubbles with only one target material on the surface (MBM and MBbi). The pGPU6/GFP/Neo-shAKT2 was used as a sample gene, which down regulate the AKT2 protein expression for the cancer therapy. It illustrated that MBiM/AKT2 had the highest gene transfection efficiency in the studied microbubbles mediated by the ultrasound, leading to the AKT2 protein expression downregulation and the strongest tumor killing effect in vitro and in vivo. In summary, a novel and biocompatible gene delivery platform via MBiM with both the endogenous and external targeting effects for breast cancer theranostics was developed.

Le texte complet de cet article est disponible en PDF.

Graphical Abstract




 : 

The iRGD dual-targeted magnetic cationic microbubble was designed to deliver the AKT2-shRNA plasmid for the enhanced ultrasound contrast imaging and improved gene therapy efficiency.


The iRGD dual-targeted magnetic cationic microbubble was designed to deliver the AKT2-shRNA plasmid for the enhanced ultrasound contrast imaging and improved gene therapy efficiency.ga1

Le texte complet de cet article est disponible en PDF.

Highlights

iRGD dual-targeted magnetic microbubbles (MBiM) designed for targeted gene delivery.
The ultrasound image intensity at the tumor site was enhanced by MBiM.
The gene therapy efficiency was improved by MBiM mediated by ultrasound.

Le texte complet de cet article est disponible en PDF.

Keywords : Ultrasound, Molecular imaging, Gene therapy, Magnetic iRGD dual-targeted, Microbubbles


Plan


© 2024  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 172

Article 116221- mars 2024 Retour au numéro
Article précédent Article précédent
  • ADSC-Exos enhance functional recovery after spinal cord injury by inhibiting ferroptosis and promoting the survival and function of endothelial cells through the NRF2/SLC7A11/GPX4 pathway
  • Shengting Wu, Zhiheng Chen, Yinghao Wu, Qiang Shi, Erzhu Yang, Baokun Zhang, Yuxuan Qian, Xiaofeng Lian, Jianguang Xu
| Article suivant Article suivant
  • S100A9-/- alleviates LPS-induced acute lung injury by regulating M1 macrophage polarization and inhibiting pyroptosis via the TLR4/MyD88/NFκB signaling axis
  • Chen Gong, Ji Ma, Ya Deng, Qiaoling Liu, Zixiang Zhan, Hong Gan, Xinjian Xiang, Meng Zhang, Kangli Cao, Tingting Shen, Lulu Fang, Bing Shen, Shichun Shen, Shenggang Ding

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.