S'abonner

Mortality Associated With Proportionality of Secondary Mitral Regurgitation After Transcatheter Mitral Valve Repair: North American Mitraclip for Functional Mitral Regurgitation Registry - 30/01/24

Doi : 10.1016/j.amjcard.2023.12.020 
Neal M. Duggal, MD a, , Milo Engoren, MD a, Scott M. Chadderdon, MD b, Evelio Rodriguez, MD c, M. Andrew Morse, MD d, Mani A. Vannan, MD e, Pradeep K. Yadav, MD e, Michael Morcos, MD f, Flora Li, MD g, Mark Reisman, MD h, Enrique Garcia-Sayan, MD i, Deepa Raghunathan, MD i, Nishtha Sodhi, MD j, Paul Sorajja, MD k, Lily Chen, MD l, Jason H. Rogers, MD l, Marcella A. Calfon, Press, MD, PhD m, Christopher P. Kovach, MD n, Edward A. Gill, MD n, Firas E. Zahr, MD b, Stanley J. Chetcuti, MD o, Yuan Yuan, MS a, Graciela B. Mentz, PhD a, D. Scott Lim, MD j, Gorav Ailawadi, MD p
a Department of Anesthesiology, University of Michigan, Ann Arbor, Michigan 
b Division of Cardiology, Knight Cardiovascular Institute, Oregon Health and Science University, Portland, Oregon 
c Department of Cardiothoracic Surgery, Ascension Saint Thomas Heart, Nashville, Tennessee 
d Division of Cardiology, Ascension Saint Thomas Heart, Nashville, Tennessee 
e Marcus Heart Valve Center, Piedmont Heart Institute, Atlanta, Georgia 
f Division of Cardiology, University of Washington, Seattle, Washington 
g Department of Anesthesiology, University of Washington, Seattle, Washington 
h Division of Cardiology, Weill Cornell Medical Center, New York, New York 
i Division of Cardiovascular Medicine, University of Texas Health Science Center at Houston, Houston, Texas 
j Division of Cardiovascular Medicine, University of Virginia, Charlottesville, Virginia 
k Valve Science Center, Minneapolis Heart Institute, Abbott Northwestern Medical Center, Minneapolis, Minnesota 
l Division of Cardiovascular Medicine, University of California Davis Medical Center, Sacramento, California 
m Division of Cardiology, University of California Los Angeles, Los Angeles, California 
n Division of Cardiology, University of Colorado, Aurora, Colorado 
o Division of Cardiovascular Medicine, University of Michigan, Ann Arbor, Michigan 
p Department of Cardiac Surgery, University of Michigan, Ann Arbor, Michigan 

Corresponding author: Tel: 734-936-4280.

Résumé

The association, if any, between the effective regurgitant orifice area (EROA) to left ventricular end-diastolic volume (LVEDV) ratio and 1-year mortality is controversial in patients who undergo mitral transcatheter edge-to-edge repair (m-TEER) with the MitraClip system (Abbott Vascular, Santa Clara, CA). This study's objective was to determine the association between EROA/LVEDV and 1-year mortality in patients who undergo m-TEER with MitraClip. In patients with severe secondary (functional) mitral regurgitation (MR), we analyzed registry data from 11 centers using generalized linear models with the generalized estimating equations approach. We studied 525 patients with secondary MR who underwent m-TEER. Most patients were male (63%) and were New York Heart Association class III (61%) or IV (21%). Mitral regurgitation was caused by ischemic cardiomyopathy in 51% of patients. EROA/LVEDV values varied widely, with median = 0.19 mm2/ml, interquartile range [0.12,0.28] mm2/ml, and 187 patients (36%) had values <0.15 mm2/ml. Postprocedural mitral regurgitation severity was substantially alleviated, being 1+ or less in 74%, 2+ in 20%, 3+ in 4%, and 4+ in 2%; 1-year mortality was 22%. After adjustment for confounders, the logarithmic transformation (Ln) of EROA/LVEDV was associated with 1-year mortality (odds ratio 0.600, 95% confidence interval 0.386 to 0.933, p = 0.023). A higher Society of Thoracic Surgeons risk score was also associated with increased mortality. In conclusion, lower values of Ln(EROA/LVEDV) were associated with increased 1-year mortality in this multicenter registry. The slope of the association is steep at low values but gradually flattens as Ln(EROA/LVEDV) increases.

Le texte complet de cet article est disponible en PDF.

Keywords : proportionality, functional mitral regurgitation, regurgitant orifice, mitral transcatheter edge-to-edge repair


Plan


 Funding: none.


© 2023  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 213

P. 99-105 - février 2024 Retour au numéro
Article précédent Article précédent
  • Respect Versus Resect Approaches for Mitral Valve Repair: A Meta-Analysis of Reconstructed Time-to-Event Data
  • Tulio Caldonazo, Michel Pompeu Sá, Xander Jacquemyn, Jef Van den Eynde, Hristo Kirov, Lamia Harik, Johannes Fischer, Dominique Vervoort, Johannes Bonatti, Ibrahim Sultan, Torsten Doenst
| Article suivant Article suivant
  • Balloon-Expandable Versus Self-Expandable Valve in Transcatheter Aortic Valve Replacement: A Nation-Wide Study
  • Young Kyoung Sa, Ik Jun Choi, Kiyuk Chang, Byung-Hee Hwang, Woo-Baek Chung, Kwan Yong Lee, Eun-Ho Choo, Chan Joon Kim, Mahn Won Park, Yoon Seok Choi, Chul Soo Park, Ki Dong Yoo, Doo Soo Jeon, Min-Ho Oak, Jungkuk Lee, Dongwoo Kang

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.