Balloon-Expandable Versus Self-Expandable Valve in Transcatheter Aortic Valve Replacement: A Nation-Wide Study - 30/01/24
Résumé |
A few studies have reported comparative analysis of clinical outcomes between balloon-expandable valve (BEV) and self-expandable valve (SEV) after transcatheter aortic valve replacement (TAVR) in patients with severe aortic stenosis using newer-generation devices. However, those reports were mostly limited to short-term outcomes and Western populations. In the present study, data of patients with severe aortic stenosis who underwent TAVR between March 2016 and December 2018 were obtained from the National Health Insurance Service in Korea. The primary end point, defined as all-cause mortality, was compared in BEV (SAPIEN 3, Edwards Lifesciences, Irvine, California) and SEV (Evolut R, Medtronic, Minneapolis, MN) groups using a propensity-score matching analysis. Cumulative event rates of ischemic stroke, repeat procedures, and permanent pacemaker insertion (PPI) were evaluated as secondary outcomes. All events were followed up to a maximum of 3 years. A total of 1,172 patients underwent transfemoral TAVR, of whom 707 (60.3%) were treated with BEV and 452 (38.6%) with SEV. After 1:1 propensity-score matching, the BEV group showed lower all-cause mortality after a median follow-up of 12.0 months (mean: 13.1 ± 9.3 months) based on Cox proportional hazard model analysis (hazard ratio [HR] 0.67, 95% confidence interval [CI] 0.45 to 0.99, p = 0.04). Cumulative incidence of ischemic stroke was not statistically different between the 2 groups (HR 0.68, 95% CI 0.29 to 1.59, p = 0.37). PPI occurred less frequently in the BEV group (HR 0.4, 95% CI 0.25 to 0.64, p < 0.01). Repeat procedures were rare (1 patient in BEV and 2 patients in SEV group). In conclusion, Korean nation-wide data analysis showed that BEV was associated with less all-cause death and incidence of PPI after TAVR than was SEV using a newer-generation device.
Le texte complet de cet article est disponible en PDF.Keywords : transcatheter aortic valve replacement, balloon-expandable valve, self-expandable valve, mortality
Plan
This work was supported by a National Research Foundation of Korea (NRF) grant funded by the Korean government (MSIT) (No. 2020R1A4A3079570), the Ministry of Education (No. 2021R1I1A1A01051425), and the Industrial Strategic Technology Development Program (No. 20014873) funded by the Ministry of Trade, Industry & Energy, Republic of Korea. |
Vol 213
P. 119-125 - février 2024 Retour au numéroBienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.