S'abonner

Gastric Aspirate Phosphatidylcholine Species in Preterm Neonates Receiving Aerosolized Surfactant - 23/11/23

Doi : 10.1016/j.jpeds.2023.113638 
Sara Koussa, BSc 1, Beena G. Sood, MD, MS 1, , Yuemin Xin, BS 1, Amit Sharma, MD 1, Krishna Rao Maddipati, PhD 2
1 Department of Pediatrics, Wayne State University School of Medicine, Detroit, MI 
2 Department of Pathology, Lipidomics Core Facility, Wayne State University School of Medicine, Detroit, MI 

Reprint requests: Beena G. Sood, MD, MS, Wayne State University School of Medicine, 540 E Canfield St, Detroit, MI 48201.Wayne State University School of Medicine540 E Canfield StDetroitMI48201

Abstract

Objective

To characterize phosphatidylcholine (PC) molecular species in serial gastric aspirates as biomarkers for lung maturity, delivery of aerosolized surfactant (AS), and need for intubation.

Methods

In a phase II clinical trial of aerosolized surfactant in preterm neonates with respiratory distress syndrome receiving noninvasive ventilation, infants received a maximum of 2 doses of nebulized beractant. Gastric aspirates were collected before and after each dose and were analyzed for PCs using liquid chromatography mass spectrometry.

Results

Of 149 infants enrolled, gastric aspirates were obtained before (n = 91) and after (n = 94) dose 1, and before (n = 56) and after (n = 57) dose 2 of nebulized beractant. The mean ± SD values of birthweight, gestational age, and age at collection of baseline gastric aspirate were 1.7 ± 0.6 kg, 31.7 ± 2.8 weeks, and 5.5 ± 1.7 hours, respectively. The most abundant PC in beractant and gastric aspirates was PC(16:0/16:0). Advancing gestational age and number of antenatal corticosteroid doses predicted increased gastric aspirate PC(16:0/16:0), whereas maternal diabetes predicted a decrease. Several PCs increased significantly (P < .05) after nebulized beractant, consistent with effective aerosol delivery. Infants who received intubation within 72 hours of birth were more likely to have lower PC(16:0/16:0) levels in baseline gastric aspirates compared with those who did not (P = .024).

Conclusions

PC molecular species in gastric aspirates of preterm neonates are potentially novel and precise biomarkers to assess lung maturity, aerosol delivery, and need for endotracheal intubation.

Le texte complet de cet article est disponible en PDF.

Abbreviations : AS, FiO2, LC-MS, NIV, PC, RDS, ROC


Plan


 Presented in part as a podium presentation at the Pediatric Academic Societies’ Annual Meeting on April 23, 2022, Denver, Colorado, and as part of the Post-Graduate on Course Surfactant Biology and Management of RDS at the Pediatric Academic Societies’ Annual Meeting on April 28, 2023, Washington, DC.


© 2023  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 263

Article 113638- décembre 2023 Retour au numéro
Article précédent Article précédent
  • In Situ Simulation and Clinical Outcomes in Infants Born Preterm
  • Ritu Chitkara, Mihoko Bennett, Janine Bohnert, Nicole Yamada, Janene Fuerch, Louis P. Halamek, Jenny Quinn, Kimber Padua, Jeffrey Gould, Jochen Profit, Xiao Xu, Henry C. Lee
| Article suivant Article suivant
  • Trends in Procedural Closure of the Patent Ductus Arteriosus among Infants Born at 22 to 30 Weeks’ Gestation
  • Zubin S. Shah, Reese H. Clark, Hanoch A. Patt, Carl H. Backes, Veeral N. Tolia

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.