Abstract

Introduction

After endotracheal intubation is performed, the location of the endotracheal tube (ETT) is confirmed followed by assessment of ETT depth. Physical examination can be unreliable and chest radiographs can lead to delayed recognition. Ultrasound may facilitate rapid determination of ETT depth at the bedside; however, the ideal technique is unknown.

Methods

This was a randomized trial comparing the static versus dynamic technique for ETT depth assessment using a cadaver model. The ETT was randomized to correct versus deep placement. Seven physicians blinded to ETT location assessed the location using static (direct visualization of an inflated cuff) versus dynamic (active inflation of the ETT cuff) visualization. Outcomes included diagnostic accuracy, time to identification, and operator confidence with subgroup analyses by physician ultrasound experience.

Results

420 total assessments were performed. The static technique was 99.1% (95% CI 94.8%–100%) sensitive and 97.1% (95% CI 91.9%–99.4%) specific. The dynamic technique was 100% (95% CI 96.7%–100%) sensitive and 100% (95% CI 96.7%–100%) specific. Time to identification was faster for the static technique (6.6 s; 95% CI 5.9–7.4 s) versus the dynamic technique (8.7 s; 95% CI 8.0–9.5 s). Operator confidence was lower for the static technique (4.4/5.0; 95% CI 4.3–4.5) versus the dynamic technique (4.7/5.0; 95% CI 4.6–4.8). There were no differences in the findings when assessed among expert or non-expert sonographers.

Conclusion

There was no statistically significant difference in the accuracy of ETT depth identification between the static or dynamic technique. However, utilizing the dynamic technique showed a statistically significant improvement in sonographer confidence and a concomitant increase in time to identification.

Le texte complet de cet article est disponible en PDF.

Keywords : Airway, Intubation, Endotracheal, Ultrasound, Depth


Plan


© 2023  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 74

P. 17-20 - décembre 2023 Retour au numéro
Article précédent Article précédent
  • Evaluation of esophageal injuries after defibrillation with transesophageal ultrasound probe in the mid-esophagus in pigs
  • Neil Krulewitz, Nicholas M. Levin, Scott Youngquist, Christopher Kelly, Guillaume Hoareau, Michael Austin Johnson, Patrick Ockerse
| Article suivant Article suivant
  • Outcome of interhospital pediatric foreign body transfers
  • Rajan Arora, Priya Spencer, Diniece Barran, David M. Merolla, Nirupama Kannikeswaran

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.