Automated brain segmentation for guidance of ultrasonic transcranial tissue pulsatility image analysis - 09/10/23

Doi : 10.1016/j.neuri.2023.100146 
Daniel F. Leotta a, , John C. Kucewicz a, Nina LaPiana b, Pierre D. Mourad b
a Applied Physics Laboratory, University of Washington, Seattle, WA 98105, USA 
b Neurological Surgery, University of Washington, Seattle, WA 98195, USA 

Corresponding author. Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle WA 98105, USA.Applied Physics LaboratoryUniversity of Washington1013 NE 40th StreetSeattleWA98105USA

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background and Objective

Tissue pulsatility imaging is an ultrasonic technique that can be used to map regional changes in blood flow in the brain. Classification of regional differences in pulsatility signals can be optimized by restricting the analysis to brain tissue. For 2D transcranial ultrasound imaging, we have implemented an automated image analysis procedure to specify a region of interest in the field of view that corresponds to brain.

Methods

Our segmentation method applies an initial K-means clustering algorithm that incorporates both echo strength and tissue displacement to identify skull in ultrasound brain scans. The clustering step is followed by processing steps that use knowledge of the scan format and anatomy to create an image mask that designates brain tissue. Brain regions were extracted from the ultrasound data using different numbers of K-means clusters and multiple combinations of ultrasound data. Masks generated from ultrasound data were compared with reference masks derived from Computed Tomography (CT) data.

Results

A segmentation algorithm based on ultrasound intensity with two K-means clusters achieves an accuracy better than 80% match with the CT data. Some improvement in the match is found with an algorithm that uses ultrasound intensity and displacement data, three K-means clusters, and addition of an algorithm to identify shallow sources of ultrasound shadowing.

Conclusions

Several segmentation algorithms achieve a match of over 80% between the ultrasound and Computed Tomography brain masks. A final tradeoff can be made between processing complexity and the best match of the two data sets.

Le texte complet de cet article est disponible en PDF.

Graphical abstract

Le texte complet de cet article est disponible en PDF.

Highlights

Automated analysis of transcranial ultrasound images identifies brain tissue.
A K-means clustering algorithm and anatomy-based processing create an ultrasound image mask for brain tissue.
The clustering algorithm incorporates both ultrasound echo strength and tissue displacement.
The ultrasound brain masks are compared to a computed tomography brain mask.

Le texte complet de cet article est disponible en PDF.

Keywords : Ultrasound, Brain, Skull, Segmentation, K-means, Clustering, Tissue pulsatility, Tissue displacement


Plan


© 2023  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 3 - N° 4

Article 100146- décembre 2023 Retour au numéro
Article précédent Article précédent
  • Functional connectivity differences in healthy individuals with different well-being states
  • Akshita Joshi, Divesh Thaploo, Henriette Hornstein, Yun-Ting Chao, Vanda Faria, Jonathan Warr, Thomas Hummel
| Article suivant Article suivant
  • Integration of eye-tracking systems with sport concussion assessment tool 5th edition for mild TBI and concussion diagnostics in neurotrauma: Building a framework for the artificial intelligence era
  • Augusto Müller Fiedler, Renato Anghinah, Fernando De Nigris Vasconcellos, Alexis A. Morell, Timoteo Almeida, Bernardo Assumpção de Mônaco, Joacir Graciolli Cordeiro

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.