S'abonner

Is a non-radiological-assisted method valid for establishing crown-root relationships in an orthodontic set-up incorporating the roots? A retrospective study - 15/09/23

Doi : 10.1016/j.ortho.2023.100792 
Mario Palone 1, Edoardo Mannelli 1, , Elena Gobbi 2, Luis Thomas Huanca Ghislanzoni 3, Francesca Cremonini 1, Luca Lombardo 1
1 Postgraduate School of Orthodontics, University of Ferrara, Via Luigi Borsari 46, 44121 Ferrara, Italy 
2 Private Practice, Falconara M.ma, 60015 Ancona, Italy 
3 Department of Orthodontics, University of Geneva, Geneva, Switzerland 

Edoardo Mannelli, Department of Orthodontics, School of Orthodontics, University of Ferrara, Via Luigi Borsari 46, 44121 Ferrara, Italy.Department of Orthodontics, School of Orthodontics, University of FerraraVia Luigi Borsari 46Ferrara44121Italy

Summary

Introduction

This study aimed to obtain information on the relationship between crown and root in terms of morphology – dimensions and crown-root angles –to be used for orthodontic set-ups without the use of radiological examinations.

Material and methods

All the good quality CBCTs of patients obeying the eligibility criteria, from 2000 to 2015, were analysed. All teeth were analysed except for third molars. Six variables were evaluated: crown (CL) and root length (RL), crown width (CW), root width (RW), crown-root angles in both the frontal (CR-frontal) and sagittal plane (CR-sagittal). All teeth were divided into 3 groups according to number of root (single, two, three-rooted). The measurements were assessed with the Invivo professional software and then, subjected to correlation matrices and linear regression statistical analysis in order to find any significant correlations between crown and root measurements (α0.05).

Results

Seventy-three out of 247 good quality CBCTs were assessed. Correlation matrices statistical analysis showed linear correlations for some variables investigated, especially for CW/RW pairing in all subgroups (r=0.81, r=0.70 and r=0.58 respectively for single-, two- and three-rooted) and CL/RL in the single-rooted subgroup (r=0.29). Subsequent linear regression analysis allowed to obtain information about roots starting from crown measurements by means of equations [RW=0.76+(0.73×CW) and RL=10.94+(0.25×CL) for single-rooted teeth; RL=1.11+(0.73×CW) and RW=0.99+(0.76×CW), respectively for single- and two-rooted teeth]. No linear correlation was found between crown measurements and C-R angular values.

Conclusion

It is possible to obtain root information starting from some crown measurements but these do not fulfil the need of minimal information to guarantee a perfect root position starting from that of crown.

Le texte complet de cet article est disponible en PDF.

Keywords : Orthodontics, Dental anatomy, Diagnosis, Treatment planning


Plan


© 2023  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 21 - N° 4

Article 100792- décembre 2023 Retour au numéro
Article précédent Article précédent
  • Treatment effectiveness of young adults using clear aligners versus buccal fixed appliances in class I malocclusion with first premolar extraction using the ABO-Objective Grading System: A randomized controlled clinical trial
  • Samer T. Jaber, Mohammad Y. Hajeer, Ahmad S. Burhan, Mohammad Khursheed Alam, Heba M. Al-Ibrahim
| Article suivant Article suivant
  • Influence of the maxillary dimensions and anterior teeth anatomy on the buccal impaction of upper permanent canines: A three-dimensional case-control study
  • Teresa Cristina Pereira de Oliveira, Flávio Mendonça Copello, Amanda Cunha Regal de Castro, Lincoln Issamu Nojima, Matilde da Cunha Gonçalves Nojima

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.