S'abonner

Comparison of the bond strength of five different composites used in the production of clear aligner attachments - 15/09/23

Doi : 10.1016/j.jormas.2023.101481 
Beyza Hancıoğlu Kircelli a, , Delal Dara Kilinc b, Ahmet Karaman c, Sanaz Sadry c, Enes Yusuf Gonul c, Hakan Gögen d
a Department of Orthodontics, School of Dental Medicine, Bahçeşehir University, Istanbul, Turkey 
b Private Practice, Istanbul, Turkey 
c Department of Orthodontics, Faculty of Dentistry, Istanbul Aydin University, Istanbul, Turkey 
d Department of Orthodontics, Faculty of Dentistry, European University of Lefke, Turkey 

Corresponding author.

Abstract

Aim

The aims of this study were to measure and compare shear bond strength (SBS) and manipulation time (MT) among five different composite resins (CR; two flowable and three highly viscous) which are used in the production of clear aligner attachments.

Material and methods

This in vitro experiment study comprised of 150 extracted premolars which were divided into 5 equal groups. Predictor variables were CRs; Tetric Evo Ceram (Ivoclar VivadentAG, Liechtenstein) (Group 1), Tetric N-Ceram; (Ivoclar VivadentAG, Liechtenstein) (Group 2), Tetric N-Flow (GC Dental Products, Tokyo, Japan) (Group 3), G-aenial Universal Injectable (GC Dental Products, Tokyo, Japan) (Group 4), GC Aligner Connect (GC Dental Products, Tokyo, Japan) (Group 5), respectively. Outcome variables were; SBS and MT for each CR attachment in each group of teeth. Oneway ANOVA was used to compare the groups. Levene's test was used to determine variance homogeneity. In terms of variance homogeneity, Bonferroni tests were used as a post-hoc test for multiple group comparisons. Results: SBS was statistically different between study groups (p < 0.001). Average SBS values ​​are found to be 16.6 ± 3.6 MPa for Tetric Evo Ceram; 20.7 ± 5.4 MPa for Tetric N-Ceram; 21.0 ± 4.0 MPa for Tetric N-Flow; 18.9 ± 5.0 MPa for G-aenial Universal Injectable; and 17.4 ± 3.5 MPa for GC Aligner Connect. The values ​​in the Tetric Evo Ceram group were significantly lower than the Tetric N-Ceram group (p = 0.004) and the Tetric N-Flow group (p = 0.001). Mean value of shear bond strength in the GC Aligner connect group were significantly lower than in the Tetric N-Ceram group (p = 0.047) and in the Tetric N-Flow group (p = 0.017). Flowable composite had a significantly shorter manipulation time than the high viscous one; mean 1,08 ± 0,22 min to mean 4,57 ± 0,51 min, respectively.

Conclusion

Although SBSs of CRs tested in the study was found to be statistically different, they all quite exceeded the accepted clinically sufficient value of 6–8 MPa. Besides, flowable composite required substantially less time to manipulate than the high viscosity composite.

Le texte complet de cet article est disponible en PDF.

Keywords : Clear aligner, Attachment, Shear bond strength, Orthodontics

Abbreviations : CR, MT, SBS, MPa, N


Plan


© 2023  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 124 - N° 6

Article 101481- décembre 2023 Retour au numéro
Article précédent Article précédent
  • Dose-dependent effects of zoledronic acid on the osteogenic differentiation of human bone marrow stem cells (hBMSCs)
  • Henrique Hadad, Henrique Rinaldi Matheus, Jason Evan Chen, Youssef Jounaidi, Francisley Ávila Souza, Fernando Pozzi Semeghini Guastaldi
| Article suivant Article suivant
  • Retrospective evaluation of traction time for impacted dilacerated maxillary central incisors in mixed dentition
  • Betul Sen Yavuz, Ahu Yilmaz, Eda Haznedaroglu, Berkant Sezer, Alev Eda Okutan, Batin Ilgit Sezgin, Mert Ozcelik, Gokce Ildes Sezgin, Faysal Ugurlu, Ali Mentes

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.