S'abonner

Treatment of supracondylar periprosthetic femoral fractures with retrograde intramedullary nailing versus distal femoral plating: A systematic review and meta-analysis of current evidence - 19/08/23

Doi : 10.1016/j.otsr.2022.103489 
Rosemary Wall a, , Farhan Syed a, Mateen Arastu a, Bryan Riemer a, Tarek Boutefnouchet b
a University Hospitals Coventry and Warwickshire NHS Trust, Clifford Bridge Road, Coventry CV2 2DX, UK 
b University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK 

*Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Supracondylar periprosthetic fractures, when amenable to fixation, can be treated by either retrograde intramedullary nailing (RIMN) or plating. There is paucity of evidence regarding the superiority of one fixation method over the other. This review aims to determine which fixation method leads to better functional outcomes and perioperative complications.

Hypothesis

Superiority of intramedullary nailing in terms of fracture healing and surgical complications when compared to distal femoral plating.

Materials and methods

Using PRISMA guidelines, a systematic search was performed. Studies which reported comparative outcome data following the two interventions were included. Qualitative data analysis and narrative synthesis were reported. Pooled comparisons were conducted when similar quantifiable outcomes were reported in a minimum of three studies.

Results

A total of 151 records were generated by the search. Eight studies met the eligibility criteria so were included in the final analysis. The studies comprised a total of 407 cases, with a follow up period ranging from 1 to 15 years. 252 cases were treated with plate fixation and 155 with RIMN. All studies were mitigated by heterogeneity and methodological limitations. The review showed marked variation in descriptive fracture classifications. Narrative data synthesis was conducted. Although guarded by the methodological limitations of individual studies, outcomes showed that mean time to union was equivalent; 5.88 months for RIMN compared to 6.75 months in plating, standardised mean difference=0.28 (95% CI –0.02–0.58). Similarly, no statistically significant differences were reported between RIMN and plating for deep infection (OR:1.41 95%CI 0.40–5.00) and revision surgery (OR: 0.74, 95%CI 0.39–1.41).

Discussion

Clinical outcomes showed a tendency that favours intramedullary nailing; however, generalisation of results was not possible. Future priority must be awarded to higher quality research in the form of a collaborative multicentre observational studies to delineate appropriate major diagnostic categories, ultimately informing a large comparative trial using condition specific validated outcome measures.

Level of evidence

III, meta-analysis.

Le texte complet de cet article est disponible en PDF.

Keywords : Periprosthetic, Femoral fracture, Locked plate, Intramedullary nail, Total knee replacement


Plan


© 2022  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 109 - N° 5

Article 103489- septembre 2023 Retour au numéro
Article précédent Article précédent
  • Trajectory of chronic and neuropathic pain, anxiety and depressive symptoms and pain catastrophizing after total knee replacement. Results of a prospective, single-center study at a mean follow-up of 7.5 years
  • Romain Priol, Gilles Pasquier, Sophie Putman, Henri Migaud, Julien Dartus, Jean-Michel Wattier
| Article suivant Article suivant
  • Femoral condyle bone mineral density in osteoarthritis differs significantly between knees with valgus vs. varus deformity
  • Grégoire Rougereau, Alexandra Villard, Tristan Langlais, Marc Delord, Philippe Boisrenoult, Nicolas Pujol

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.