S'abonner

Validation of a novel finite-element model for evaluating patellofemoral forces and stress during squatting after posterior-stabilized total knee arthroplasty - 19/08/23

Doi : 10.1016/j.otsr.2022.103519 
Salah Mebarki a, Franck Jourdan a, François Canovas b, Etienne Malachanne a, Louis Dagneaux a, b,
a Laboratoire de mécanique et génie civil (LMGC), CNRS, Montpellier University of Excellence (MUSE), 860, rue de St-Priest, 34090 Montpellier, France 
b Department of Orthopaedic Surgery, Lower limb Surgery Unit, Lapeyronie University Hospital, Montpellier University, 371, avenue Gaston-Giraud, 34295 Montpellier, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

Several studies have documented the relationship between patellofemoral pain and patient dissatisfaction after total knee arthroplasty (TKA). However, few computer simulations have been designed to evaluate the patellofemoral joint during flexion. The aim of this study was to validate a new computational simulation, driven by forces and moments, and to analyze patellofemoral reaction forces and stress under squat loading conditions after TKA implantation.

Hypothesis

This computational simulation of a squat using a model driven by forces and moments is comparable to in vitro and in silico data from the literature.

Material and methods

We developed a finite element model of the lower limb after implantation of a fixed-bearing posterior-stabilized TKA. To simulate squat loading conditions when standing on both legs, an initial load of 130N was applied to the center of the femoral head. Quadriceps force, patellofemoral contact force and Von Mises stress on the patellar implant, tibiofemoral contact forces and pressure on the tibial insert, and post-cam contact force were evaluated from 0° to 100° of knee flexion.

Results

Quadriceps force increased during flexion, up to 6 times the applied load. Von Mises stress on patellar implant increased up to 16MPa at 100° flexion. Tibiofemoral contact forces increased up to 415 N medially and 339 N laterally, with 64% distributed medially on the tibial insert. Post-cam contact started slightly before 70° of flexion.

Discussion

In this simulation, tibiofemoral, patellofemoral and post-cam contact forces, and pressure distribution on the tibial insert were consistent with various published studies. This agreement suggests that computational simulation driven by forces and moments can reproduce squat loading conditions during knee flexion after TKA, without experimental kinematic data used to drive the simulation.

Conclusion

This study represents an initial step towards validating tibiofemoral and patellofemoral mechanical behavior under squat conditions, from this computational simulation driven by forces and moments. This model will help us better understand the influence of various implantation techniques on patellofemoral forces and stress during flexion.

Level of evidence

IV, biomechanical computational study.

Le texte complet de cet article est disponible en PDF.

Keywords : Computational model, Biomechanics, Knee replacement, Alignment, Patellofemoral

Abbreviations : TKA, FEM, CAD, N, MPa


Plan


© 2022  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 109 - N° 5

Article 103519- septembre 2023 Retour au numéro
Article précédent Article précédent
  • Patellar medial-lateral position can be used to correct the effect of leg rotation on preoperative planning in total knee arthroplasty for varus knees
  • Shinichiro Nakamura, Shota Takemoto, Shinichi Kuriyama, Kohei Nishitani, Hiromu Ito, Mutsumi Watanabe, Young Dong Song, Shuichi Matsuda
| Article suivant Article suivant
  • Preoperative flexion contracture does not affect outcome in total knee arthroplasty: A case-control study of 2,634 TKAs
  • Andrea Fernandez, Elliot Sappey-Marinier, Jobe Shatrov, Cécile Batailler, Philippe Neyret, Denis Huten, Elvire Servien, Sébastien Lustig

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.