S'abonner

Measure of lung dielectric proprieties in patients with Idiopathic Pulmonary Fibrosis: correlation with clinical, radiological and pulmonary functional parameters - 12/08/23

Doi : 10.1016/j.rmed.2023.107370 
Filippo Patrucco a, b, , Carlo Albera c, d, Mattia Bellan b, e, Martina Zava a, Francesco Gavelli b, Piero Emilio Balbo a, b, 1, Paolo Solidoro c, d, 1
a Respiratory Diseases Unit, Medical Department, AOU Maggiore della Carità di Novara, Novara, Italy 
b Translational Medicine Department, University of Eastern Piedmont, Novara, Italy 
c Medical Sciences Department, University of Turin, Turin, Italy 
d Respiratory Diseases Unit, Cardiovascular and Thoracic Department, AOU Città della Salute e della Scienza di Torino, Turin, Italy 
e Division of Internal Medicine, Medical Department, AOU Maggiore della Carità di Novara, Novara, Italy 

Corresponding author. Respiratory Diseases Unit, Medical Department, AOU Maggiore della Carità Hospital, 28100, C.so Mazzini 18, Novara, Italy.Respiratory Diseases UnitMedical DepartmentAOU Maggiore della Carità HospitalC.so Mazzini 18Novara28100Italy

Abstract

Background

Dielectric properties of biological tissues are biophysical parameters; in lung they change with amount of air, blood and parenchyma. Remote Dielectric Sensing (ReDS™) technology measures dielectric properties of lung tissues quantifying the content of fluids inside the scan volume. We aimed to evaluate the reliability of ReDS™ measure in Idiopathic Pulmonary Fibrosis (IPF) patients and in healthy volunteers, and to investigate the correlation of ReDS™ score with clinical, radiological and functional parameters.

Methods

We conducted a prospective observational study, including 52 patients with diagnosis of IPF and 17 healthy volunteers; for each patient we recorded: complete functional evaluation, dyspnoea score (mMRC scale), Usual Interstitial Pneumonia (UIP) Computed Tomography (CT) pattern (UIP definite or probable) and ReDS™ measure (expressed in %).

Results

ReDS™ measure was reported as correct both in patients and controls, the firsts with higher scores (33.8% vs 29.1%, p = 0.003). In IPF patients we observed a significant inverse correlation with ReDS™ score and Forced Vital Capacity (FVC), Vital Capacity (VC) and Total Lung Capacity (TLC) measures and, when we considered only patients with UIP definite CT pattern, the correlation was inverse with FVC, VC, TLC, DLCO. In IPF patients the higher was mMRC dyspnoea index, the higher was ReDS™ score. No significant correlations were observed between ReDS™ score and functional parameters in healthy controls.

Discussion

We demonstrated a correlation of ReDS™ scores with some functional (mainly indicative or diagnostic for restriction) and clinical parameters in IPF patients; the score was correlated with density of tissues possibly quantifying tissue fibrosis in IPF patients.

Le texte complet de cet article est disponible en PDF.

Highlights

Lung dielectric proprieties are influenced by lung water content.
Their non-invasive measure is performed with Remote Dielectric Sensing (ReDS™) technology.
ReDS™ measure correlates with functional restrictive parameters in IPF patients.
ReDS™ measure correlates also with CT UIP pattern and dyspnea in IPF patients.

Le texte complet de cet article est disponible en PDF.

Keywords : Dielectric proprieties, Idiopathic pulmonary fibrosis, Restrictive pattern, Spirometry, Usual interstitial pneumonia

Abbreviations : CPI, CT, DLCO, FEV1, FVC, HRCT, mMRC, ReDS, TLC, VC, UIP, VA


Plan


© 2023  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 217

Article 107370- octobre 2023 Retour au numéro
Article précédent Article précédent
  • Muscle mass cross-sectional area is associated with survival outcomes in malignant pleural disease related to lung cancer
  • Austin M. Meggyesy, Candice L. Wilshire, Shu-Ching Chang, Jed A. Gorden, Christopher R. Gilbert
| Article suivant Article suivant
  • STOP-Bang for OSA screening in patients with pulmonary hypertension
  • Thomas H. Fox, Michael LaNasa, Lesley Ann Saketkoo, Shigeki Saito, Bennett P. deBoisblanc, Matthew R. Lammi

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.