S'abonner

A comparative evaluation of the quality of cryoprecipitate prepared from 350 ml versus 450 ml of whole blood and different methods of thawing of plasma: A prospective observational study - 13/07/23

Doi : 10.1016/j.tracli.2023.06.002 
M. Sree Bhagavathi a, Satya Prakash a, Gaurav Chhabra b, Ansuman Sahu a, Debasish Mishra a, Somnath Mukherjee a,
a Department of Transfusion Medicine, All India Institute of Medical Sciences, Bhubaneswar, India 
b Department of Pathology and Laboratory Medicine, All India Institute of Medical Sciences, Bhubaneswar, India 

Corresponding author at: Department of Transfusion Medicine, All India Institute of Medical Sciences, Bhubaneswar, Odisha, India.Department of Transfusion MedicineAll India Institute of Medical SciencesBhubaneswarOdishaIndia

Highlights

No standardized guideline exists for preparing cryoprecipitate from 350 ml of whole blood.
The thawing method of plasma for the preparation of cryoprecipitates is also controversial.
The cryobath method of plasma thawing resulted in a better factor VIII yield, and the blood bank refrigerator method resulted in a higher fibrinogen yield.
Over 75% of the cryoprecipitates prepared from 350 ml whole blood passed the quality criteria.
350 ml whole blood collection from low body weight (<55 kg) donors could be utilized to prepare cryoprecipitates.

Le texte complet de cet article est disponible en PDF.

Abstract

Introduction

Cryoprecipitate is used in conditions like hypofibrinogenemia, massive transfusion with bleeding, and factor XIII deficiency. The current guidelines support the preparation of cryoprecipitate from 450 ml whole blood. But 350 ml of whole blood collection is expected from low body weight (<55 kg) donors. However, no standardized criteria exist for preparing cryoprecipitate from 350 ml of whole blood.

Aim of the study

This study compared the fibrinogen and factor VIII levels in cryoprecipitate units prepared from 350 ml versus 450 ml whole blood collection. The study also compared the fibrinogen and factor VIII levels prepared by circulating water bath versus blood bank refrigerator (BBR) thawing method.

Methodology

A total of 128 blood bags were equally divided into groups A and B for 450 and 350 ml whole blood collection further subdivided into subgroups based on thawing methods. The fibrinogen and factor VIII yield were analyzed in the cryoprecipitates prepared from both groups.

Results

The factor VIII levels were significantly higher in cryoprecipitate made from 450 ml whole blood collection (P = 0.02). The BBR method of plasma thawing resulted in better fibrinogen recovery than the cryo bath method. Whereas vice versa in the case of factor VIII recovery. A weak but significant positive correlation was noted in factor VIII levels with the plasma volume.

Conclusion

Over 75% of the cryoprecipitates prepared from 350 ml whole blood passed the fibrinogen and factor VIII quality control criteria. So, 350 ml whole blood collection from low body weight (<55 kg) donors could be utilized to prepare cryoprcipitates. However, future clinical studies should focus on the cryoprecipitate's clinical efficacy prepared from 350 ml of whole blood.

Le texte complet de cet article est disponible en PDF.

Keywords : Cryoprecipitate, Factor VIII, Quality control, Fibrinogen, Body weight


Plan


© 2023  Société française de transfusion sanguine (SFTS). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 30 - N° 3

P. 329-334 - août 2023 Retour au numéro
Article précédent Article précédent
  • Determination of Rh type and gender using circulating cell-free fetal DNA in early pregnancy of Rh negative women in turkey
  • Tugba Elgun, Yasemin Musteri Oltulu, Asiye Gok Yurttas, Umut Agyuz, Fulya Ozkal Molla, Ulkan Kilic
| Article suivant Article suivant
  • A novel hepcidin mutation
  • Louis Praeger-Jahnsen, Karin Magnussen, Frank Vinholt Schiødt, Rikke Christina Therkildsen, Niels Jørgensen, Lennart Friis-Hansen

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.