S'abonner

Screening for impaired pulmonary function using peak expiratory flow: Performance of different interpretation strategies - 06/06/23

Doi : 10.1016/j.resmer.2023.101015 
Martin Rune Hassan Hansen a, b, c, d, , Johannes Martin Schmid e
a Department of Medicine, Randers Regional Hospital, Skovlyvej 15, DK-8930 Randers NØ, Denmark 
b Environment, Occupation and Health, Department of Public Health, Aarhus University, Bartholins Allé 2, DK-8000 Aarhus C, Denmark 
c Danish Big Data Centre for Environment and Health (BERTHA), Aarhus University, Frederiksborgvej 399, Postboks 358, DK-4000 Roskilde, Denmark 
d Department of Infectious Diseases, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, DK-8200 Aarhus N, Denmark 
e Department of Respiratory Diseases and Allergy, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, DK-8200 Aarhus N, Denmark 

Corresponding author.

Abstract

Background

Spirometry is the gold standard for diagnosis of impaired pulmonary function, but is often unavailable in resource-constrained settings. Some authors have suggested using peak expiratory flow (PEF) to screen for impaired pulmonary function when spirometry is unavailable, but with no consensus on how to define abnormally low PEF. Strategies have included cutoffs based on absolute value of PEF, PEF in percent predicted, PEF Z-score, PEF × height−2, and gender-specific cutoffs of absolute PEF. The objective of this paper is to determine the PEF interpretation strategy with the highest predictive ability for low pulmonary function, with spirometry as the gold standard.

Methods

We analyzed data on individuals aged 40–79 years in the United States National Health and Nutrition Examination Survey 2007–2012. 6,144 individuals fulfilled inclusion criteria for the main analysis. For each PEF interpretation strategy, we calculated the area under the receiver operating curve (AUC) for the detection of low pulmonary function (defined by FEV1 Z-score < -1.645, < -2, < -2.5 or < -3).

Results

The AUC was substantially and statistically significantly higher for PEF in percent predicted and PEF Z-score than for absolute value and PEF × height−2, including after stratification by gender. There was no difference in AUC between PEF in percent predicted and PEF Z-score.

Conclusion

If using PEF to screen adults aged 40 years or older for impaired pulmonary function defined by low FEV1 Z-score, basing cutoffs on PEF in percent predicted or PEF Z-score may result in improved predictive ability. As percent predicted is a mathematically simpler term than Z-score, it may be preferable to use cutoffs based on PEF in percent predicted.

Le texte complet de cet article est disponible en PDF.

Keywords : Peak expiratory flow, Pulmonary function test, Chronic obstructive pulmonary disease, National Health and Nutrition Examination Survey, Centers for Disease Control and Prevention

Abbreviations : AUC, COPD, FEV1, FVC, PEF, ROC


Plan


© 2023  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 83

Article 101015- juin 2023 Retour au numéro
Article précédent Article précédent
  • Outcomes of extended resection for locally advanced thymic malignancies
  • Jean Baptiste Menager, Olaf Mercier, Antonin Levy, Angela Botticella, Pauline Pradère, Dominique Fabre, Justin Issard, Charles Naltet, David Planchard, Fabrice Barles, Vincent De Montpreville, Cécile Le Pechoux, Benjamin Besse, Elie Fadel, for International Center for Thoracic Cancers (CICT) Rare Tumors Hub Working Group
| Article suivant Article suivant
  • Assessment of functional respiratory complaints and related factors in people with hypermobile Ehlers-Danlos syndrome: Cross-sectional study
  • Sara Reina-Gutiérrez, Gilles Caty, Ana Torres-Costoso, Laurent Pitance, Daniel H Manicourt, Gregory Reychler

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.