S'abonner

Molecular diagnosis of Tuberculous meningitis: sdaA-based multi-targeted LAMP and GeneXpert Ultra - 29/05/23

Doi : 10.1016/j.tube.2023.102339 
Bhavana Yadav a, 1, Megha Sharma b, 1, Neeraj Singla c, 1, Ritu Shree c, Manoj Goyal c, Tanish Modi d, Ananya Sharma d, Aman Sharma e, Navneet Sharma f, Pallab Ray a, Manish Modi c, Kusum Sharma a,
a Department of Microbiology, Postgraduate Institute of Medical Education and Research, Chandigarh, India 
b Department of Microbiology, All India Institute of Medical Sciences, Bilaspur, HP, India 
c Department of Neurology, Postgraduate Institute of Medical Education and Research, Chandigarh, India 
d Government Medical College and Hospital, Sector 32, Chandigarh, India 
e Department of Internal Medicine, Postgraduate Institute of Medical Education and Research, Chandigarh, India 
f Department of Emergency Medicine, Postgraduate Institute of Medical Education and Research, Chandigarh, India 

Corresponding author. Department of Medical Microbiology, Post Graduate Institute of Medical Education and Research, Chandigarh, India.Department of Medical MicrobiologyPost Graduate Institute of Medical Education and ResearchChandigarhIndia

Abstract

Setting

Nucleic acid amplification techniques like GeneXpert and GeneXpert Ultra (Xpert Ultra), the first-line tests for diagnosing Tuberculous meningitis (TBM), are expensive and depend on sophisticated equipment.

Objective

The diagnostic potential of multitargeted loop-mediated isothermal assay (MLAMP), a low-cost simple test using novel gene combination, was evaluated for TBM.

Design

300 CSF specimen (200 TBM patients, 100 controls) processed between January 2017 and December 2021 were subjected to MLAMP (using sdaA, IS1081 and IS6110 gene targets), sdaA PCR and Xpert Ultra. The performance was evaluated against uniform case definition as per Marais criteria, and against culture.

Results

Uniform case definition classified 50 as definite TBM and 150 as probable or definite TBM. Against this uniform case definition, the sensitivity and specificity of MLAMP was 88% and 100%, respectively. The sensitivity was 96% against culture-positive cases and 85.3% against culture-negative cases. The sensitivity of sdaA-LAMP, IS1081-LAMP, IS6110-LAMP, Xpert Ultra and sdaA-PCR was 82.5%, 80.5%, 85.3%, 67% and 71%, respectively against uniform case definition. sdaA-LAMP detected additional two cases and IS1081-LAMP detected nine. 11 of 134 (8.2%) cases were reported rifampicin resistant by Xpert Ultra.

Conclusion

MLAMP, incorporating sdaA and IS1081, is a cheap, easy and accurate first-line diagnostic test for TBM.

Le texte complet de cet article est disponible en PDF.

Keywords : sdaA, GeneXpert ultra, Rifampicin resistance, LAMP


Plan


© 2023  Elsevier Ltd. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 140

Article 102339- mai 2023 Retour au numéro
Article précédent Article précédent
  • Identification of N6-methylandenosine-related lncRNA for tuberculosis diagnosis in person living with human immunodeficiency virus
  • Shaohua Xu, Huicheng Yuan, Ling Li, Kai Yang, Liangcun Zhao
| Article suivant Article suivant
  • Acquired drug resistance during the turnaround time for drug susceptibility testing impacts outcome of tuberculosis
  • Jiahui Zhu, Jia Liu, Ziwei Bao, Hong Cao, Sainan Wang, Xuliang Li, Zhu Ning, Sven Hoffner, Yi Hu, Lina Davies Forsman

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.