L. Tordjman 1, , Y. Bohbot 1, 2, J. Dreyfus 3, T. Le Tourneau 4, Y. Lavie-Badie 5, C. Selton-Suty 6, B. Elegamandji 3, G. L’official 7, A. Fraix 5, S. Aghezzaf 8, P.Y. Turgeon 4, D. Messika Zeitoun 9, M. Enriquez-Sarano 10, A. Coisne 11, 12, E. Donal 7, C. Tribouilloy 1, 2
1 Department of Cardiology, Amiens University Hospital, Amiens, France 
2 Jules-Verne University of Picardie, Ur Upjv 7517, Amiens, France 
3 Cardiology Department, centre cardiologique du Nord, Saint-Denis, France 
4 Inserm, CNRS, institut du thorax, université Nantes, Nantes, France 
5 Department of Cardiology, Rangueil University Hospital, 31000 Toulouse, France 
6 Cardiology Department Cic-Ec, CHU de Nancy-Brabois, 54000 Nancy, France 
7 Inserm, Ltsi-Umr 1099, CHU de Rennes, University of Rennes, 35000 Rennes, France 
8 Inserm, U1011-Egid, institut Pasteur de Lille, CHU de Lille, University Lille, 59000 Lille, France 
9 Department of Cardiology, University Of Ottawa Heart Institute, On K1y 4w7, Ottawa, Canada 
10 Valve Science Center, Minneapolis Heart Institute Foundation, Minneapolis, MN, USA 
11 Inserm, U1011-Egid, institut Pasteur de Lille, CHU de Lille, University Lille, 59000 Lille, France 
12 Cardiovascular Research Foundation, New York 

Corresponding author.

Résumé

Introduction

Various definitions of very severe (VS) tricuspid regurgitation (TR) have been proposed based on the effective regurgitant orifice area (EROA) or tricuspid coaptation gap (TCG). Because of the inherent limitations associated with the EROA, we hypothesized that the TCG would be more suitable for defining VSTR and predicting outcomes.

Method

In this French multicentre retrospective study, we included 606 patients with ≥ moderate-to-severe isolated functional TR (without structural valve disease or an overt cardiac cause) according to the recommendations of the European Association of Cardiovascular Imaging. Patients were further stratified into VSTR according to the EROA (≥ 60 mm2) and then according to the TCG (≥ 10mm). The primary endpoint was all-cause mortality and the secondary endpoint was cardiovascular mortality.

Results

The relationship between the EROA and TCG was poor (R2=0.22), especially when the size of the defect was large. Four-year survival was comparable between patients with an EROA < 60 mm2 vs. ≥ 60 mm2 (68±3% vs. 64±5%, P=0.89). A TCG ≥ 10mm was associated with lower four-year survival than a TCG < 10mm (53±7% vs. 69±3%, P<0.001). After adjustment for covariates, including comorbidity, symptoms, dose of diuretics, and right ventricular dilatation and dysfunction, a TCG ≥ 10mm remained independently associated with higher all-cause mortality (adjusted HR [95%CI]=1.47 [1.13–2.21], P=0.019) and cardiovascular mortality (adjusted HR [95%CI]=2.12 [1.33–3.25], P=0.001), whereas an EROA ≥ 60 mm2 was not associated with all-cause or cardiovascular mortality (adjusted HR [95%CI]: 1.16 [0.81–1.64], P=0.416, and adjusted HR [95%CI]: 1.07 [0.68–1.68], P=0.784, respectively).

Conclusion

The correlation between the TCG and EROA is weak and decreases with increasing defect size. A TCG ≥ 10mm is associated with increased all-cause and cardiovascular mortality and should be used to define VSTR in isolated functional TR (Fig. 1).

Le texte complet de cet article est disponible en PDF.

Plan


© 2023  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 15 - N° 3

P. 246 - juin 2023 Retour au numéro
Article précédent Article précédent
  • Randomized study for the optimal treatment of symptomatic patients with low gradient severe aortic valve stenosis and preserved left ventricular ejection fraction (ROTAS trial)
  • E. Galli, A. Coisne, F. Le Ven, C. Sportuch, O. Lairez, A. Bernard, E. Oger, E. Le Pabic, E. Donal
| Article suivant Article suivant
  • Effectiveness of a radiation protective device of interventional echocardiographers during structural heart disease interventions
  • F. Magniez, N. Piriou, P. Jaafar, P.Y. Tuergon, C. Cueff, M. Bertrand, J.M. Langlard, L. Legloan, L. Ammour, P. Guerin

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.