S'abonner

Successful restoration of corneal surface integrity with a tissue-engineered allogeneic implant in severe keratitis patients - 29/04/23

Doi : 10.1016/j.biopha.2023.114612 
Carmen González-Gallardo a, b, Juliana Martínez-Atienza c, Beatriz Mataix d, José Ignacio Muñoz-Ávila a, J. Daniel Martínez-Rodríguez e, Santiago Medialdea e, Antonio Ruiz-García c, f, Antonio Lizana-Moreno c, f, Salvador Arias-Santiago c, f, Manuel de la Rosa-Fraile g, Ingrid Garzon b, h, Antonio Campos b, h, Natividad Cuende c, i, Miguel Alaminos b, h, , Miguel González-Andrades a, j, , Rosario Mata c
a Ophthalmology Clinical Unit of San Cecilio University Hospital, Granada, Spain 
b Instituto de Investigación Biosanitaria ibs.GRANADA, Granada, Spain 
c Andalusian Network for the Design and Translation of Advanced Therapies (former Andalusian Initiative for Advanced Therapies) – Fundación Andaluza Progreso y Salud, Junta de Andalucía, Seville, Spain 
d Ophthalmology Clinical Unit of Virgen Macarena University Hospital, Seville, Spain 
e Ophthalmology Clinical Unit of Virgen de las Nieves University Hospital, Granada, Spain 
f Cell Therapy and Tissue Engineering Unit, Virgen de las Nieves University Hospital, Granada, Spain 
g University Hospital Virgen de las Nieves, Microbiology Service, Emeritus, Spain 
h Tissue Engineering Group, Department of Histology, Universidad de Granada, Granada, Spain 
i Andalusian Transplant Coordination, Servicio Andaluz de Salud, Seville, Spain 
j Maimonides Biomedical Research Institute of Cordoba (IMIBIC), Department of Ophthalmology, Reina Sofia University Hospital and University of Cordoba, Cordoba, Spain 

Correspondence to: Universidad de Granada, Tissue Engineering Group-Department of Histology, Faculty of Medicine, Avenida de la Investigación 11, Torre A, planta 5ª, E18016 Granada, Spain.Universidad de Granada, Tissue Engineering Group-Department of Histology, Faculty of MedicineAvenida de la Investigación 11, Torre A, planta 5ªGranadaE18016Spain⁎⁎Correspondence to: Maimonides Biomedical Research Institute of Cordoba (IMIBIC), Avenida Menéndez Pidal s/n, E14004 Cordoba, Spain.Maimonides Biomedical Research Institute of Cordoba (IMIBIC)Avenida Menéndez Pidal s/nCordobaE14004Spain

Abstract

Objectives

Corneal diseases are among the main causes of blindness, with approximately 4.6 and 23 million patients worldwide suffering from bilateral and unilateral corneal blindness, respectively. The standard treatment for severe corneal diseases is corneal transplantation. However, relevant disadvantages, particularly in high-risk conditions, have focused the attention on the search for alternatives.

Methods

We report interim findings of a phase I-II clinical study evaluating the safety and preliminary efficacy of a tissue-engineered corneal substitute composed of a nanostructured fibrin-agarose biocompatible scaffold combined with allogeneic corneal epithelial and stromal cells (NANOULCOR). 5 subjects (5 eyes) suffering from trophic corneal ulcers refractory to conventional treatments, who combined stromal degradation or fibrosis and limbal stem cell deficiency, were included and treated with this allogeneic anterior corneal substitute.

Results

The implant completely covered the corneal surface, and ocular surface inflammation decreased following surgery. Only four adverse reactions were registered, and none of them were severe. No detachment, ulcer relapse nor surgical re-interventions were registered after 2 years of follow-up. No signs of graft rejection, local infection or corneal neovascularization were observed either. Efficacy was measured as a significant postoperative improvement in terms of the eye complication grading scales. Anterior segment optical coherence tomography images revealed a more homogeneous and stable ocular surface, with complete scaffold degradation occurring within 3–12 weeks after surgery.

Conclusions

Our findings suggest that the surgical application of this allogeneic anterior human corneal substitute is feasible and safe, showing partial efficacy in the restoration of the corneal surface.

Le texte complet de cet article est disponible en PDF.

Graphical Abstract




ga1

Le texte complet de cet article est disponible en PDF.

Highlights

NANOULCOR human bioartificial corneas can be surgically implanted in human patients.
Bioartificial human corneas are highly biocompatible and free from side effects.
Preliminary signs of efficacy were found in the first cases grafted with NANOULCOR.

Le texte complet de cet article est disponible en PDF.

Keywords : Tissue bioengineered cornea, Clinical trial, Corneal transplantation, Severe keratitis, Limbal stem cell deficiency


Plan


© 2023  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 162

Article 114612- juin 2023 Retour au numéro
Article précédent Article précédent
  • TG2 promotes amyloid beta aggregates: Impact on ER-mitochondria crosstalk, calcium homeostasis and synaptic function in Alzheimer’s disease
  • Jessica Panes-Fernandez, Pamela A. Godoy, Javiera Gavilan, Oscar Ramírez-Molina, Carlos Felipe Burgos, Ana Marileo, Oscar Flores-Núñez, Patricio A. Castro, Gustavo Moraga-Cid, Gonzalo E. Yévenes, Carola Muñoz-Montesino, Jorge Fuentealba
| Article suivant Article suivant
  • A potential anti-HIV-1 compound, Q308, inhibits HSV-2 infection and replication in vitro and in vivo
  • Xin Zhang, Axin Li, Ting Li, Zeren Shou, Yibin Li, Xinman Qiao, Ruijing Zhou, Xuelin Zhong, Songshan Li, Lin Li

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.