Abstract

Background

Motorized lengthening nails are the treatment standard for bone lengthening of the lower limbs. However, bony changes namely osteolysis and periosteal hypertrophy have been described after certain type of magnetically driven lengthening nails. The aim of this study was to estimate the proportion rate of radiological bone abnormalities of Fitbone TAA femoral or tibial lengthening nails with a minimum follow-up time of 1 year.

Hypothesis

The bone surrounding the telescopic junction of Fitbone lengthening nails does not exhibit osteolysis or periosteal reactions. The bone surrounding the locking screws exhibits cortical hypertrophy.

Patients and methods

Single-centre retrospective case series of patients treated with a Fitbone nails with a minimum follow-up of 1 year after implantation. Standard orthogonal radiographs were obtained postoperatively, weekly during the distraction phase, and then monthly for 6 months, and before removal of the equipment. We looked for bone abnormalities at the telescoping junction of the nail and at the locking screws before removal.

Results

In total, 101 patients (58 males, 43 females) with a mean age of 21 years (range: 11.8–53.5) had 128 (101 femoral and 27 tibial) limb lengthening nails implanted between 2010 and 2021. The mean follow-up period was 925 days (range: 371–3587). The mean lengthening was 4.7cm (range: 1.5–8.0). No bones exhibited focal osteolysis or periosteal reactions at the telescopic junction of the lengthening nail. Cortical hypertrophy at the locking screws was observed in significantly more Fitbone nails than previously reported, i.e., 101/128 (79%).

Discussion

Neither focal osteolysis, nor periosteal reactions were observed at the bone surrounding the telescopic junction of 128 Fitbone lengthening nails. Cortical hypertrophy around the single diaphyseal locking screw was observed in 101/128 (79%) of the cases. These absences of osteolytic changes after long term observation are reassuring for both surgeons and patients alike.

Level of evidence

IV.

Le texte complet de cet article est disponible en PDF.

Keywords : Limb lengthening, Limb reconstruction, FITBONE, Motorized intramedullary lengthening nail, Leg Length Inequality, Limb Deformities, Congenital, Postoperative Complications, Osteolysis


Plan


© 2022  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 109 - N° 3

Article 103501- mai 2023 Retour au numéro
Article précédent Article précédent
  • Combined lengthening for acquired leg length discrepancy: Are there advantages of hydroxyapatite-coated intramedullary nails?
  • Arnold Popkov, Szymon Pietrzak, Alexander Antonov, Tomasz Parol, Mikan Lazović, David Podeszwa, Dmitry Popkov
| Article suivant Article suivant
  • Quantitative analysis of lower limb and pelvic deformities in children with X-linked hypophosphatemic rickets
  • Aurore Bonnet-Lebrun, Agnès Linglart, Marine De Tienda, Younes Ouchrif, Jugurtha Berkenou, Ayman Assi, Philippe Wicart, Wafa Skalli

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.