S'abonner

The Burden of Cardiac Implantable Electronic Device Checks in the Peri-MRI Setting: The CHECK-MRI Study - 28/02/23

Doi : 10.1016/j.hlc.2022.10.005 
Bradley M. Pitman, BSc a, b , Jonathan Ariyaratnam, MB, BChir a, b, Kerry Williams, MMRT b, Michelle Evans, MHlthEc&Policy c, Nicole Reid-Smith, BBME b, Lauren Wilson, BSc b, Karen Teo, MBBS, PhD b, Glenn D. Young, MBBS a, b, Kurt C. Roberts-Thomson, MBBS, PhD a, b, Christopher X. Wong, MBBS, MPH, PhD a, b, Prashanthan Sanders, MBBS, PhD a, b, Dennis H. Lau, MBBS, PhD a, b,
a Centre for Heart Rhythm Disorders, University of Adelaide, Adelaide, SA, Australia 
b Department of Cardiology, Royal Adelaide Hospital, Adelaide, SA, Australia 
c Southern Area Local Health Network, Adelaide, SA, Australia 

Corresponding author at: Department of Cardiology, Royal Adelaide Hospital, 1 Port Rd, Adelaide, SA 5000, AustraliaDepartment of CardiologyRoyal Adelaide Hospital1 Port RdAdelaideSA5000Australia

Abstract

Background

Most modern cardiac implantable electronic device (CIED) systems are now compatible with magnetic resonance imaging (MRI) scans. The requirement for both pre- and post-MRI CIED checks imposes significant workload to the cardiac electrophysiology service. Here, we sought to determine the burden of CIED checks associated with MRI scans.

Methods

We identified all CIED checks performed peri-MRI scans at our institution over a 3-year period between 1 July 2017 to 30 June 2020, comprising three separate financial years (FY). Device check reports, MRI scan reports and clinical summaries were collated. The workload burden was determined by assessing the occasions and duration of service. Analysis was performed to determine cost burden/projections for this service and identify factors contributing to the workload.

Results

A total of 739 CIED checks were performed in the peri-MRI scan setting (370 pre- and 369 post-MRI scan), including 5% (n=39) that were performed outside of routine hours (weekday <8 am or >5 pm, and weekends). MRIs were performed for 295 patients (75±13 years old, 64% male) with a CIED (88% permanent pacemaker, and 12% high voltage device), including 49 who had more than one MRI scan. The proportion of total MRI scans for patients with a CIED in-situ increased each FY (from 0.5% of all MRIs in FY1, to 0.9% in FY2, to 1.0% in FY3). The weekly workload increased (R2=0.2, p<0.001), but with week-to-week variability due to ad hoc scheduling (209 days with only one MRI vs 78 days with ≥2 MRIs for CIED patients). The projected annual cost of this service will increase to AUD$161,695 in 10 years for an estimated annual 546 MRI scans for CIED patients.

Conclusions

There is an increasing workload burden and expense associated with CIED checks in the peri-MRI setting. Appropriate budgeting, staff allocation and standardisation of automated CIED pre-programming features among manufacturers are urgently needed.

Le texte complet de cet article est disponible en PDF.

Keywords : Magnetic resonance imaging, Cardiac implantable electronic devices, Permanent pacemakers, Implantable cardioverter-defibrillators


Plan


© 2022  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 32 - N° 2

P. 252-260 - février 2023 Retour au numéro
Article précédent Article précédent
  • Three Zone Scanning Protocol For Lung Ultrasound: An Anatomical Basis
  • Alistair G. Royse, Elaine Lui, Dayu Gai, Ximena Cid, David Canty, Andrew Wang, Lindsay Bridgford, Colin F. Royse
| Article suivant Article suivant
  • The Australian and New Zealand Cardiac Implantable Electronic Device Survey, Calendar Year 2021: 50-Year Anniversary
  • Harry G. Mond, Ian Crozier, J. Graeme Sloman

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.