S'abonner

In multiple sclerosis, a Functional Independence Measure ≥ 107 is the best predictor of outcome after clean intermittent catheterization training - 22/02/23

Doi : 10.1016/j.rehab.2022.101636 
Rebecca Haddad a, b, , Philippe Lagnau a, Camille Chesnel a, Gabriel Miget a, Matthieu Grasland a, Frédérique Le Breton a, Gérard Amarenco a, Claire Hentzen a
a Sorbonne Universté, GRC 001, GREEN Groupe de Recherche Clinique en Neuro-Urologie, AP-HP, Hôpital Tenon, F-75020 Paris, France 
b Faculty of Medicine and Health Sciences, Department of Human Structure and Repair, Ghent University, Ghent, Belgium 

Corresponding author at: Hôpital Tenon, Service de Neuro-Urologie, 4 Rue de la Chine, 75020 Paris, France.Hôpital Tenon, Service de Neuro-Urologie4 Rue de la ChineParis75020France

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Highlights

People with multiple sclerosis (PwMS) should be assessed for the ability for clean intermittent catheterization (CIC) training.
The functional independence measure (FIM) and pencil and paper test are independent predictors of successful CIC training.
The diagnostic performance of these tools to screen failures differ significantly.
The tools have similar sensitivity and a large effect size.
An FIM value ≥107/126 has the best specificity.

Le texte complet de cet article est disponible en PDF.

Abstract

Background

Assessment of motor and cognitive functions is recommended before clean intermittent catheterization training. Two validated instruments, the Functional Independence Measure (FIM) and the Pencil and Paper Test (PP-Test), are associated with the ability to learn self-catheterization in people with multiple sclerosis.

Objectives

We aimed to compare the performance of these tools in predicting the outcome of clean intermittent catheterization training in multiple sclerosis.

Methods

All people with multiple sclerosis attending a tertiary neuro-urology department between 2011 and 2019 and eligible for clean intermittent catheterization were included in this retrospective study. The reference standard was the ability to perform at least 2 trials of self-catheterization at the end of the training session. The 2 index tests, the FIM and PP-Test, were administered before the teaching session. Their diagnostic performance was estimated by calculating sensitivity, specificity, and area under the receiver operating characteristic curve (AUC). The AUC values were compared by a two-sided DeLong test.

Results

We included 395 individuals (mean [SD] age 49.8 [12] years; 70% women). At the end of the session, 87% of the patients succeeded in learning self-catheterization. The optimal cut-offs for the FIM (107) and PP-Test (13) were estimated, resulting in sensitivity of 73% (95% confidence interval [68–77) and 73% (67–77) and specificity 73% (59–84) and 63% (49–76), respectively. The AUC values for the FIM and PP-Test were significantly different (0.79 vs 0.73, p = 0.049). The effect size was large for both the FIM (Cohen's d = 1.14) and PP-Test (Cohen's d = 0.87).

Conclusions

An FIM value ≥107 has the best specificity to predict outcome after clean intermittent catheterization training for people with multiple sclerosis. The sensitivity of the FIM and PP-Test is similar, and both have a large effect size for the outcome of self-catheterization training in multiple sclerosis.

Le texte complet de cet article est disponible en PDF.

Keywords : Neurogenic lower urinary tract dysfunction, Clean intermittent catheterization, Functional independence measure, Disability, Multiple sclerosis

Abbreviations : CIC, PwMS, PP-Test, FIM, EDSS, ROC, AUC, SD


Plan


© 2022  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 66 - N° 1

Article 101636- février 2023 Retour au numéro
Article précédent Article précédent
  • Home-based respiratory muscle training on quality of life and exercise tolerance in long-term post-COVID-19: Randomized controlled trial
  • Tamara del Corral, Raúl Fabero-Garrido, Gustavo Plaza-Manzano, César Fernández-de-las-Peñas, Marcos Navarro-Santana, Ibai López-de-Uralde-Villanueva
| Article suivant Article suivant
  • Risk factors for rotator cuff disease: A systematic review and meta-analysis of diabetes, hypertension, and hyperlipidemia
  • Ayush Giri, Deirdre O'Hanlon, Nitin B. Jain

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.