S'abonner

Comparing the effect of demineralized versus hybrid dentin matrices on inducing bone regeneration in New Zealand white rabbits' Mandibular defect - 11/02/23

Doi : 10.1016/j.jormas.2022.11.022 
Eman Elkady a, c, Ragia Nour El-den a, d, Ayman Atiba b, e, Sarah Yasser a, f,
a Oral Biology Department, Faculty of Dentistry, Tanta university, Egypt 
b Department of Surgery, Anesthesiology and Radiology, Faculty of Veterinary Medicine, Kafrelsheikh University, Kafrelsheikh, Egypt 
c Demonstrator of Oral Biology, Faculty of Dentistry, Tanta University, Tanta, Egypt 
d Professor of Oral Biology, Faculty of Dentistry, Tanta University, Tanta, Egypt 
e Professor of Surgery, Anesthesiology and Radiology, Faculty of Veterinary Medicine, Kafrelsheikh University 
f Assistant Professor of Oral Biology, Faculty of Dentistry, Tanta University, Tanta, Egypt 

Corresponding author.

Highlights

Rounded defect (10 mm in diameter and 5 mm in depth) in mandibular bone of rabbits is considered a critical size bone defect.
Demineralized dentin matrix act as an osteoinductive scaffold for bone regeneration.
Mixing demineralized dentin matrix and undemineralized dentin matrix has a synergetic effect on improving bone regeneration due to combining the advantages of both matrices.

Le texte complet de cet article est disponible en PDF.

Abstract

Objectives

The aim of this study was to compare the effect of using demineralized dentin matrix (DDM) versus hybrid dentin matrices; Demineralized and undemineralized dentin particles (DDM +UDDM) on inducing bone regeneration in mandibular defects.

Design

The study was conducted on fifty adult New Zealand rabbits, twenty for preparation of experimental materials and thirty for surgical procedures. They were randomly assigned into 3 equal groups as follow one control group: no treatment and two experimental groups including demineralized group: treated with DDM only; and hybrid group: treated with a hybrid of (50% DDM+50% UDD). A rounded critical size defect (10 mm in diameter- 5 mm in depth) was created in the body of mandible. After 3- and 6-weeks post-surgery, the bone regeneration was evaluated by light microscope, scanning electron microscope and histomorphometry.

Results

Histological, histomorphometrical observation and SEM revealed that both dentin matrices had largely resorbed and induced new bone formation at both experimental groups compared to the control group, with statistically higher percentage of new bone formation in the hybrid group.

Conclusion

We concluded that although both dentin matrices induced new bone formation; however, hybrid dentin matrix yielded better results compared to DDM group.

Le texte complet de cet article est disponible en PDF.

Keywords : Bone regeneration, Demineralized dentin matrix, Hybrid dentin matrix, Critical size bone defect

Abbreviation : Demineralized dentin matrix, Undemineralized dentin particles, Energy dispersive X-ray, Light microscopic, Bone morphogenetic proteins


Plan


© 2022  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 124 - N° 1S

Article 101346- février 2023 Retour au numéro
Article précédent Article précédent
  • Immunotherapy for oral cancer treatment through targeting of IDO1 and its pathway
  • Balachander Kannan, Vijayashree Priyadharsini Jayaseelan, Paramasivam Arumugam
| Article suivant Article suivant
  • Evaluation of trephine osteotomy technique in direct sinus lifting with simultaneous implant placement
  • Hala A. Hamed, Ahmed M. Shaaban, Lydia N. Melek

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.