S'abonner

Positive predictive values of ultrasound-guided fine-needle aspiration with parathyroid hormone assay and Tc-99m sestamibi scintigraphy in sporadic primary hyperparathyroidism - 02/02/23

Doi : 10.1016/j.anorl.2022.07.001 
J.-M. Prades a, , Y. Lelonge a, B. Farizon a, S. Chatard b, N. Prevot-Bitot c, M. Gavid a
a Service ORL et de chirurgie cervico-faciale, CHU, Saint-Étienne, France 
b Service imagerie médicale – clinique mutualiste, Saint-Étienne, France 
c Service de médecine nucléaire, CHU, Saint-Étienne, France 

Corresponding author.

Abstract

Objectives

Ultrasonography (US) and Tc-99m sestamibi scintigraphy (SS) are usually performed as preoperative imaging modalities for patients with sporadic primary hyperparathyroidism (SPHP). Fine-needle aspiration (FNA) under US guidance for parathyroid hormone (PH) assay can enhance the diagnostic accuracy of US. The main aim of the present study was to compare positive predictive values between US-FNA and SS. The secondary aim was to draw up a decision-tree for FNA and SS.

Methods

The single-center retrospective study included patients with previously non-operated SPHP. They underwent US-guided FNA, PET-CT SS, and 18 F-choline scintigraphy if the first two methods were inconclusive. PH washout level was considered pathological when greater than the serum PH level. Postoperative histology data were correlated to imaging data.

Results

In total, 117 patients were included, with a mean age of 64 years (range, 26–89 years). A single adenoma was identified on pathology in 101 patients (89%). FNA findings were pathologic for 64 patients (55%), with a mean PH level of 2,604ng/L [range, 585–9,074ng/L], higher than the serum level of 179ng/L [range, 60–1,000ng/L]. US-guided FNA showed sensitivity, specificity, and positive and negative predictive values (PPV, NPV) of respectively 72%, 92%, 99% and 28%, compared to 89%, 42%, 93% and 32% for SS. The rate of error in locating the parathyroid gland was 8% for US-guided FNA versus 12% for SS. Comparison of the two methods showed better sensitivity for SS (P=0.0052) and better specificity for FNA (P=0.0143), with no significant difference in PPV or NPV. 18 F-choline scintigraphy detected the hyperfunctioning parathyroid in 11 out of the 15 patients.

Conclusion

PPV did not significantly differ between FNA and SS. US-guided FNA performed by an experienced operator could be a simple first-line method for more than 50% of patients with non-operated SPHP, with 99% PPV. In case of negative or doubtful FNA findings, SS can be performed in second line.

Le texte complet de cet article est disponible en PDF.

Keywords : Primary hyperparathyroidism, Ultrasonography, Fine-needle aspiration, Parathyroid hormone assay, Sestamibi scintigraphy


Plan


© 2022  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 140 - N° 1

P. 3-7 - janvier 2023 Retour au numéro
Article précédent Article précédent
  • Polish your title and abstract!
  • O. Laccourreye, R. Jankowski
| Article suivant Article suivant
  • Contribution of the Synkinesis Assessment Questionnaire and the Sunnybrook Facial Grading System to the evaluation of synkinesis after peripheral facial palsy: A STROBE observational study
  • E. Lannadère, D. Picard, R. Hervochon, F. Tankéré, G. Lamas, P. Gatignol

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.