S'abonner

Quantified flow and angioarchitecture show similar associations with hemorrhagic presentation of brain arteriovenous malformations - 25/01/23

Doi : 10.1016/j.neurad.2022.01.061 
Chung-Jung Lin , a, b , Ko-Kung Chen a, Yong-Sin Hu b, c, Huai-Che Yang c, d, Chun-Fu Lin c, d, Feng-Chi Chang a, b
a Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan 
b School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan 
c Department of Radiology, Taipei Veterans General Hospital Taoyuan Branch, Taoyuan, Taiwan 
d Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan 

Corresponding author at: Department of Radiology, Taipei Veterans General Hospital No. 201, Shipai Rd., Sec. 2, Beitou District, Taipei 112, Taiwan.Department of RadiologyTaipei Veterans General Hospital No. 201Shipai Rd., Sec. 2, Beitou District, Taipei 112Taiwan

Abstract

Introduction

The purpose of our study was to elucidate the impact of brain arteriovenous malformation (BAVM) flow and wall shear stress (WSS) on angioarchitecture and to evaluate their association with hemorrhagic presentations.

Materials and methods

Forty-one patients with BAVMs were evaluated by phase-contrast MR angiography. Volume flow rate and WSS were quantified. Angioarchitectural features such as location, angiogenesis, venous stenosis, venous ectasia, venous phlebitis, venous rerouting, exclusive deep vein and venous sac were evaluated by two neuroradiologists. The correlation between BAVM flow and size was evaluated with Spearman correlation coefficients. Differences of size, flow, and WSS between the hemorrhagic and non-hemorrhagic groups, the seizure and non-seizure groups, and between the different groups based on angioarchitecture were evaluated with Mann-Whitney U tests. Accuracy in predicting hemorrhage was evaluated with receiver operating characteristic curves.

Result

BAVM flow was highly correlated with volume (ρ = 0.77). Higher flow was more commonly associated with angiogenesis, venous ectasia, venous rerouting, and venous phlebitis. Flow and angioarchitecture showed similar efficacy in differentiating hemorrhagic from non-hemorrhagic BAVMs. WSS did not demonstrate differences across any clinical groups.

Conclusion

Flow quantification and angioarchitecture analysis of BAVMs showed similar efficacy as evaluated by associations with hemorrhagic presentation. High flow affects both arterial and venous angioarchitecture, reflecting the nature of low vascular resistance in BAVMs.

Le texte complet de cet article est disponible en PDF.

Graphical abstract




Image, graphical abstract

Le texte complet de cet article est disponible en PDF.

Highlights

Flow quantification of BAVMs outperformed nidal volumetric measurement in hemorrhagic risk assessment.
High flow affects both arterial and venous angioarchitecure, reflecting the nature of low vascular resistance in BAVMs.

Le texte complet de cet article est disponible en PDF.

Keywords : Angioarchitecture, Brain arteriovenous malformation, Flow, Size, Wall shear stress

Abbreviations : BAVM, DSA, WSS


Plan


© 2022  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 50 - N° 1

P. 79-85 - février 2023 Retour au numéro
Article précédent Article précédent
  • Experimental evaluation of the performance of large bore aspiration catheters
  • Philippe Reymond, Olivier Brina, Gaurav Girdhar, Oscar Bolanos, Karl-Olof Lovblad, Paolo Machi
| Article suivant Article suivant
  • Rehearsals using patient-specific 3D-printed aneurysm models for simulation of endovascular embolization of complex intracranial aneurysms: 3D SIM study
  • Anthony Le Bras, Fakhreddine Boustia, Kevin Janot, Estelle Le Pabic, Mathilde Ouvrard, Claire Fougerou-Leurent, Jean-Christophe Ferre, Jean-Yves Gauvrit, François Eugene

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.