S'abonner

Platypnoea Orthodeoxia Syndrome and Patent Foramen Ovale Closure: Single-Centre Experience and Long-Term Follow-Up - 24/11/22

Doi : 10.1016/j.hlc.2022.07.003 
Ana Gama e Castro, MD b, 1, André Luz, MD, PhD, FESC a, b, c, , 1 , Filomena Oliveira, MD a, b, Bruno Brochado, MD a, b, Raquel Santos, MD a, b, André Alexandre, MD a, b, Andreia Campinas, MD a, b, David Sá Couto, MD a, b, João Silveira, MD a, b, Severo Torres, MD a, b
a Department of Cardiology, Centro Hospitalar Universitário do Porto (CHUPorto), Porto, Portugal 
b ICBAS School of Medicine and Biomedical Sciences, Porto University, Porto, Portugal 
c Cardiovascular Research Group – Unit of Multidisciplinary Investigation in Biomedicine, ICBAS, Porto University, Porto, Portugal 

Corresponding author at: Cardiology Department, Largo Prof. Abel Salazar, 4099-001 Porto, Portugal.Cardiology DepartmentLargo Prof. Abel SalazarPorto4099-001Portugal

Abstract

Introduction

Platypnoea orthodeoxia syndrome (POS) is an uncommon condition characterised by dyspnoea and arterial desaturation induced by an upright position and relieved in the supine position, usually due to a patent foramen ovale (PFO). Percutaneous closure of a PFO is the preferred treatment to cure POS. This study aimed to evaluate the clinical and gasometrical characteristics and to describe the long-term outcomes of percutaneous PFO closure in a group of patients with POS.

Methods

Patients with POS and a PFO treated by percutaneous intervention from 2010–2020 were reviewed. The primary efficacy outcome was the arterial oxygen pressure to fraction of inspired oxygen (PaO2/FiO2) ratio before and 24 hours after the procedure. Total clinical success was considered if the arterial oxygen saturation measured by pulse oximetry (SpO2) improved to >94% in the supine and sitting positions without supplemental oxygen, while partial success was considered if SpO2 improved from baseline but still required oxygen to achieve >94%. Secondary outcomes were an absolute improvement in SpO2 and sense of dyspnoea, without significant residual shunt on transthoracic echocardiography (TTE) at follow-up.

Results

Of 168 patients undergoing PFO or atrial septal defect closure, 14 had POS (8.3%). Percutaneous PFO closure was successfully performed in all patients with a single device. Twelve of 14 patients had total clinical success (86%) and one patient had partial success. The PaO2/FiO2 ratio increased from 155.9±50.6 to 318.3±73.4 after PFO closure (p=0.002). All patients with total clinical success had a successful secondary efficacy outcome with an absolute improvement in SpO2 and complete resolution of dyspnoea, which was maintained at follow-up (37±20 months; range, 11 months to 6 years). None had a significant residual shunt between 12 and 24 months of follow-up.

Conclusion

The PFO percutaneous closure was a successful, durable and safe method for patients presenting with POS; it achieved major improvements in both gasometrical parameters and quality of life.

Le texte complet de cet article est disponible en PDF.

Keywords : Patent foramen ovale, PFO, Platypnoea-orthodeoxia syndrome, Hypoxaemia, Right-to-left shunting


Plan


© 2022  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 31 - N° 11

P. 1547-1552 - novembre 2022 Retour au numéro
Article précédent Article précédent
  • Risk Factors of Haematoma Formation Following Cardiac Implantable Electronic Device Procedures
  • Benjamen Wang, Jessica Yao, Anver Sethwala, Joshua Hawson, Irene Stevenson
| Article suivant Article suivant
  • A Modified Maze Versus Cut-and-Sew Maze for Long-Standing Persistent Atrial Fibrillation Concomitant with Mitral Valve Surgery: A Propensity Score-Matched Cohort Study
  • Huishan Wang, Jinsong Han

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.