Comparison of five methods for locked-plate fixation of complex diaphyseal fractures - 26/10/22

Doi : 10.1016/j.otsr.2022.103400 
Marie Pierret a, b, Henri Favreau a, François Bonnomet a, Daniel Elizondo Moreno b, c, Nadia Bahlouli b, Pierre Martz d, e, Matthieu Ehlinger a, b,
a Service de Chirurgie Orthopédique et de Traumatologie, Hôpital de Hautepierre, Hôpitaux Universitaires de Strasbourg, 1 avenue Molière, 67098 Strasbourg cedex, France 
b Laboratoire ICube, Université de Strasbourg- CNRS, 2 rue Boussingault, 67000 Strasbourg, France 
c Plateforme IRIS/ICube, Université de Strasbourg- CNRS, 1 place de l’hôpital, 67000 Strasbourg, France 
d CHU Dijon, service d’orthopédie traumatologie, 14 rue Paul Gaffarel, 21000 Dijon, France 
e Unité INSERM UMR CAPS U1093. UFR STAPS, - BP 27877, Campus Universitaire, 21078 Dijon Cedex, France 

*Corresponding author. Service de Chirurgie Orthopédique et de Traumatologie, Hôpital de Hautepierre, Hôpitaux Universitaires de Strasbourg, 1 avenue Molière, 67098 Strasbourg cedex, France.Service de Chirurgie Orthopédique et de Traumatologie, Hôpital de Hautepierre, Hôpitaux Universitaires de Strasbourg1 avenue MolièreStrasbourg cedex67098France

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Peri-prosthetic fractures (PPFs) are steadily rising in number due to population ageing and increased performance of joint replacement procedures. Although PPFs without implant loosening are usually managed by internal fixation, no consensus exists regarding the optimal construct. The primary objective of this study was to compare five constructs, and the secondary objective was to compare sub-groups of mono-cortical screw constructs, with the goal of identifying the method most appropriate for diaphyseal fracture fixation when prosthetic material is present within the intra-medullary canal.

Hypothesis

The primary hypothesis was that fixation using bi-cortical screws, i.e., the current reference standard, was superior over other fixation methods. The secondary hypothesis was that adding double cerclage to mono-cortical screw fixation provided the greatest mechanical strength.

Materials and methods

Synthetic osteoporotic bone was used to compare five methods for locking-screw fixation of a femoral diaphyseal plate. One method involved bi-cortical screws and four methods mono-cortical screws, with no cerclage wire, a single cerclage wire on either side positioned near or at a distance from the fracture, and two cerclage wires on both sides of the fracture. A complex fracture was simulated by creating a 2-cm diaphyseal gap. Load-to-failure was determined by applying compression loading along the anatomical axis of the femur.

Results

Bi-cortical screw fixation provided greater mechanical strength than did three of the four mono-cortical screw constructs. The exception was the mono-cortical-screw and double-cerclage construct, for which no significant difference was found compared to bi-cortical screw fixation. Thus, mono-cortical screw fixation with double cerclage may be the best alternative when presence of an implant in the intra-medullary canal precludes bi-cortical screw fixation.

Conclusion

The findings from this study have clear implications for clinical practice. The study hypotheses were partly confirmed. The absence of a significant difference between the reference-standard bi-cortical screw fixation method and mono-cortical screw fixation with double cerclage, combined with the results regarding the secondary objective, suggest that mono-cortical screws plus double cerclage deserve preference in patients with an intra-medullary implant. Clinical studies are needed to assess the results of this bench study.

Level of evidence

IV, bench study.

Le texte complet de cet article est disponible en PDF.

Keywords : Biomechanics, Femoral fracture, Plate fixation, Periprosthetic fracture


Plan


© 2022  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 108 - N° 7

Article 103400- novembre 2022 Retour au numéro
Article précédent Article précédent
  • No difference in clinical and radiological outcomes following fixation of transverse patella fractures with either suture tape or metallic cerclage: A retrospective comparative study
  • Edoardo Monaco, Adnan Saithna, Silvia Cardarelli, Giorgio Bruni, Alessandro Carrozzo, Alessandro Annibaldi, Matthew Daggett, Andrea Del Duca, Andrea Ferretti
| Article suivant Article suivant
  • Tibia fracture management in low-resource settings using the External Fixation and Traction Device of the Guinean Military Health Service
  • Damany Keita, Nicolas de l’Escalopier, Léopold Lamah, Sandaly Diakite, Keita Fodé Ibrahima Kourala, Paul Koulemou, Moustapha Conde

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.