Three-dimensional imaging of the distal radius with reference to volar locking plate surgery - 26/10/22

Doi : 10.1016/j.otsr.2022.103372 
Koichiro Mizuno , Kotaro Sato, Gaku Takahashi, Yoshikuni Mimata, Kenya Murakami, Minoru Doita
 Iwate Medical University, Iwate Ika Daigaku, Japan 

Corresponding author. Department of Orthopaedic Surgery, Iwate Medical University, 2-1-1, Idaidori, Yahaba-cho, Shiwa-gun, Iwate 028-3694, Japan.Department of Orthopaedic Surgery, Iwate Medical University, 2-1-1, Idaidori, Yahaba-cho, Shiwa-gunIwate028-3694Japan

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Highlights

The higher the volar lunate facet, the more proximal is the volar locking plate.
The height of the volar lunate facet was correlated with the volar cortical angle.
The plate fits at the ulnar side, whereas the radial side has more space.

Le texte complet de cet article est disponible en PDF.

Abstract

Background

The watershed line is widely accepted as the distal limit of the volar locking plate (VLP); however, the VLP placement could vary depending on the plate contour and morphology of the distal radius. The aim of this study was to investigate the morphology of the distal radius and VLP fitting using 3D images.

Hypothesis

We hypothesized that attachment of the VLP would affect the contour of the volar prominence of the distal radius.

Patients and methods

Variable-angle LCP two-column volar distal radius Plate 2.4 and 16 formalin-fixed cadavers were studied. The plate and forearm were scanned using a computed tomography scanner. The plate was fixed to the radial shaft in the most distal position without flexor pollicis longus tendon contact. Postero-antero and lateral radiographs were obtained using fluoroscopy. Postero-antero radiographs were superimposed on a 3D image of the distal radius. The virtual plate was attached to the distal radius in the computer simulations and the plate was adjusted in the sagittal plane. In the postero-antero radiographs, the distance between the plate and distal end of the radius (DPR) was measured. In the sagittal plane, the height of the volar lunate facet (VLF) and the plate-to-bone distance of each locking screw hole was measured. The volar cortical angle (VCA) was measured as the angle formed by a line drawn along the volar surface and a line drawn on the radial shaft on the sagittal plane at each locking screw plane.

Results

A significant correlation was observed between the height of the VLF and the DPR and between the height of the VLF and the VCA. The plate-to-bone distance at the ulnar screw hole was significantly smaller than that of the other screw holes.

Discussion

Our study revealed that the higher the VLF, the more proximal is the VLP. The plate fits on the bone surface at the ulnar side, whereas the radial side has more space between the plate and bone.

Level of Evidence

III, diagnostic Level.

Le texte complet de cet article est disponible en PDF.

Keywords : Distal radius fracture, Volar locking plate, Morphology of the distal radius, Three-dimensional evaluation, Computer simulation


Plan


© 2022  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 108 - N° 7

Article 103372- novembre 2022 Retour au numéro
Article précédent Article précédent
  • Masquelet's induced membrane technique associated with Reamer Irrigation Aspiration grafting and intramedullary Nailing (MaRIAN) for chronic diaphyseal osteomyelitis of the lower limb
  • Marianne Cuvillier, Jean-François Meucci, Céline Cazorla, Anne Carricajo, Thomas Neri, Bertrand Boyer
| Article suivant Article suivant
  • Description of unusual osteochondral laminar fragment patterns in Distal Radius fractures
  • Agustín Guillermo Donndorff, Virginia Maria Cafruni, Pedro Bronenberg Victorica, Gerardo Luis Gallucci, Jorge Guillermo Boretto, Pablo De Carli

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.