Abstract

Aim

We sought to develop a model to measure the acceleration and jerk vectors affecting the performance of High-Quality Cardiopulmonary Resuscitation (HQ-CPR) during patient transport.

Methods

Three participants completed a total of eighteen rounds of compression only HQ-CPR in a moving vehicle. The vehicle was driven in a manner that either minimized or increased linear and angular vectors. The HQ-CPR variables measured were compression fraction (CF%), and percentages of compressions with correct depth > 5 cm (D%), rate 100–120 (R%), full recoil (FR%), and hand position (HP%). A composite HQ-CPR score was calculated: ((D% + R% + FR% + HP%)/4) * CF%). Linear and gyroscopic data were measured in the X, Y, and Z axes. The perceived difficulty in performing HQ-CPR was measured with the Borg Rating of Perceived Exertion Scale.

Results

HQ-CPR data, linear vector data, and gyroscopic data were successfully recorded in all trial evolutions. Univariate regression analysis demonstrated that HQ-CPR was negatively affected by increasing magnitudes of linear acceleration (B = −0.093%/m/s2, 95% CI [−0.17 – −0.02), p = 0.02], linear jerk (B = −0.134%/m/s3, 95% CI [−0.26 – −0.01], p = 0.04), angular velocity (B = −0.543%/radian/s, 95% CI [−0.98 – −0.11], p = 0.02), and angular acceleration (B = 0.863%/radian/s2, 95% CI [−1.69 – −0.03], p = 0.04). Increasing vectors were negatively associated with FR% and R%. No difference was seen in D%, HP%, or CF%. Borg Rating of Perceived Exertion was greater in dynamic driving evolutions (8 ± 1 vs 3.5 ± 1.53, p = 0.02).

Conclusion

This model reliably measured linear and angular off-balancing vectors experienced during the delivery of HQ-CPR in a moving vehicle. In this preliminary report, compression rate and full recoil appear to be HQ-CPR variables most affected in a moving vehicle.

Le texte complet de cet article est disponible en PDF.

Keywords : Cardiopulmonary resuscitation, Off-balancing vectors, Out-of-hospital cardiac arrest, Transportation, Acceleration, Jerk


Plan


© 2022  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 61

P. 158-162 - novembre 2022 Retour au numéro
Article précédent Article précédent
  • Post-traumatic symptoms in patients with acute coronary syndrome: Maybe an outcome predictor after the ED visit!
  • Noureddine Rekik, Sirine Bouzid, Amine Abdelhedi, Kais Bouzid, Mouna Benamor, Feres Benamira, Rim Karray, Mouna Jerbi, Abdennour Nasri, Olfa Chakroun-Walha
| Article suivant Article suivant
  • Can a voice assistant help bystanders save lives? A feasibility pilot study chatbot in beta version to assist OHCA bystanders
  • Martín Otero-Agra, Cristina Jorge-Soto, Óscar J. Cosido-Cobos, Jorge Blanco-Prieto, Cristian Alfaya-Fernández, Enrique García-Ordóñez, Roberto Barcala-Furelos

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.