A systematic review of the validity of non-invasive sleep-measuring devices in mid-to-late life adults: Future utility for Alzheimer's disease research - 12/10/22

Doi : 10.1016/j.smrv.2022.101665 
Sebastian Francis Green a, b, c, , Tory Frame d, Luke Vikram Banerjee a, Amy Gimson b, Jonathan Blackman a, b, Hamish Morrison a, b, Katie Lloyd a, b, Sarah Rudd e, William George Frederick Fotherby f, Ullrich Bartsch g, h, Shaun Purcell i, Matt Jones j, Liz Coulthard a, b,
a Bristol Medical School, University of Bristol, Bristol, UK 
b Department of Neurology, Southmead Hospital, North Bristol NHS Trust, Bristol, UK 
c Department of Neurology, David Geffen School of Medicine, University of California, Los Angeles, USA 
d Department of Computer Science, University of Bath, Bath, UK 
e Library and Knowledge Service, Southmead Hospital, North Bristol NHS Trust, Bristol, UK 
f Manchester Metropolitan University, Manchester, UK 
g UK Dementia Research Institute, Care Research & Technology Centre, Imperial College London and University of Surrey, Guildford, UK 
h Surrey Sleep Research Centre, Department of Clinical and Experimental Medicine, Faculty of Health and Medical Sciences, University of Surrey, Guildford, UK 
i Department of Psychiatry, Brigham and Women's Hospital, Harvard Medical School, Harvard University, USA 
j School of Physiology, Pharmacology & Neuroscience, University of Bristol, Bristol, UK 

Corresponding author. Bristol Medical School, University of Bristol, Bristol, UK.Bristol Medical SchoolUniversity of BristolBristolUK∗∗Corresponding author. Bristol Medical School, University of Bristol, Bristol, UK.Bristol Medical SchoolUniversity of BristolBristolUK

Abstract

Changes in sleep during mid-to-late life are associated with risk for Alzheimer's disease (AD). Mechanistic understanding of this association necessitates measurement tools able to quantify these sleep changes longitudinally and accurately. We conducted a systematic review with meta-analysis of validity studies of non-invasive sleep-measuring devices published since 2015 that record sleep metrics associated with AD in adults over 40 (mean 52.9, SD 6.1 years). We reviewed 52 studies, including 32 wearable and ten non-wearable single or multi-sensor devices validated against polysomnography (minimum one night). The apnoea hypopnoea index and oxygen desaturation index were accurately measured across devices. Total sleep time and sleep efficiency were significantly overestimated (p < 0.001) by mean 33.2 minutes and 7.6%, respectively. Slow wave sleep duration was inaccurately measured except by a headband device with electroencephalography. There was no significant difference in accuracy between participants with and without sleep disorders. Studies were undermined by high risk of bias from closed-access algorithms and classification thresholds, and incomplete reporting of accuracy data. Only one study investigated slow wave activity, and none investigated sleep spindles. Nonetheless, we have identified devices that could be used in future studies of sleep and AD risk and discuss some of the limitations of available research.

Le texte complet de cet article est disponible en PDF.

Keywords : Sleep, Alzheimer's, NREM, REM, Slow wave, Apnoea, Hypopnoea


Plan


© 2022  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 65

Article 101665- octobre 2022 Retour au numéro
Article précédent Article précédent
  • The prevalence of depression in isolated/idiopathic rapid eye movement sleep behavior disorder: A systematic review and meta-analysis
  • Yukiyoshi Sumi, Fumi Masuda, Hiroshi Kadotani, Yuji Ozeki
| Article suivant Article suivant
  • Persistence and prevalence of sleep-disordered breathing after delivery: A scoping review of longitudinal and cross-sectional studies
  • Kim-Tai Lui, R. John Kimoff, Pattaraporn Panyarath, Sushmita Pamidi

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.