S'abonner

French Imaging Database Against Coronavirus (FIDAC): A large COVID-19 multi-center chest CT database - 30/09/22

Doi : 10.1016/j.diii.2022.05.006 
Loic Boussel a, b, , Jean-Michel Bartoli c, Samy Adnane a, Jean-François Meder d, e, Patrick Malléa f, Jeremy Clech f, Marc Zins g, Jean-Paul Bérégi h
a Department of Radiology, Croix-Rousse Hospital, Hospices Civils de Lyon, 69004 Lyon, France 
b Univ Lyon, INSA Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, 69100 Villeurbanne, France 
c Department of Radiology, Aix-Marseille University, University Hospital La Timone, AP-HM, 13385 Marseille, France 
d Department of Neuroimaging, Sainte-Anne Hospital, 75013 Paris, France 
e Université Paris Cité, 75006 Paris, France 
f NEHS DIGITAL, 92240 Malakoff, France 
g Department of Radiology, Paris Saint-Joseph Hospitals, 75014 Paris, France 
h Department of Medical Imaging, University Hospital of Nîmes, 30900 Nîmes, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Highlights

The FIDAC database includes chest CT examinations and metadata from 5944 patients with or suspected of COVID-19 infection.
Among the 5944 patients, 44.6% are positive for COVID-19 on reverse transcription-PCR tests.
FIDAC database is available in open access through the CERF-SFR website (https://cerf.radiologie.fr/contact).

Le texte complet de cet article est disponible en PDF.

Abstract

Purpose

During the first wave of the COVID-19 pandemic, the French Society of Radiology and the French College of Radiology, in partnership with NEHS Digital, have set up a system to collect chest computed tomography (CT) examinations with clinical, virological and radiological metadata, from patients clinically suspected of COVID-19 pneumonia. This allowed the constitution of an anonymized multicenter database, named FIDAC (French Imaging Database Against Coronavirus). The aim of this report was to describe the content of this public database.

Materials and methods

Twenty-two French radiology centers participated to the data collection. The data collected were chest CT examinations in DICOM format associated with the following metadata: patient age and sex, originating facility identifier, originating facility region, time from symptom onset to CT examination, indication for CT examination, reverse transcription-polymerase chain reaction (RT-PCR) results and normalized CT report performed by a senior radiologist. All the data were anonymized and sent through a NEHS Digital system to a centralized data center.

Results

A total of 5944 patients were included from the 22 centers aggregated into 8 regions with a mean number of patients of 743 ± 603.3 [SD] per region (range: 102–1577 patients). Reasons for CT examination and normalized CT reports were provided for all patients. RT-PCR results were provided in 5574 patients (93.77%) with a positive result of RT-PCR in 44.6% of patients.

Conclusion

The FIDAC project allowed the creation of a large database of chest CT images and metadata available, under conditions, in open access through the CERF-SFR website.

Le texte complet de cet article est disponible en PDF.

Keywords : Computed tomography, COVID-19, Database, Multicenter studies

Abbreviations : COVID-19, CT, CERF, DICOM, FIDAC, GGO, RT-PCR, SFR


Plan


© 2022  Société française de radiologie. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 103 - N° 10

P. 460-463 - octobre 2022 Retour au numéro
Article précédent Article précédent
  • The BUMPy road of peritoneal metastases in ovarian cancer
  • Stephanie Nougaret, Elizabeth Sadowski, Yulia Lakhman, Pascal Rousset, Max Lahaye, Michael Worley, Olivia Sgarbura, Atul B. Shinagare
| Article suivant Article suivant
  • Early enlarging cavitation after percutaneous radiofrequency ablation of lung tumors: Incidence, risk factors and outcome
  • Koji Tomita, Toshihiro Iguchi, Yusuke Matsui, Mayu Uka, Noriyuki Umakoshi, Toshiharu Mitsuhashi, Jun Sakurai, Hideo Gobara, Susumu Kanazawa, Takao Hiraki

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.