Sentinel lymph node biopsy with a handheld cordless magnetic probe following preoperative MR lymphography using superparamagnetic iron oxide for clinically N0 early oral cancer: A feasibility study - 29/09/22

Abstract |
Purpose |
Radioisotope (RI) tracers are generally used for preoperative mapping of sentinel lymph node (SLN) and intraoperative detection with a portable γ probe. However, the use of RI has several limitations. Therefore, a method without RI is required for the widespread application of SLN biopsy. The purpose of this study was to evaluate the feasibility of SLN biopsy with a handheld cordless magnetic probe following magnetic resonance lymphography (MRL) using superparamagnetic iron oxide (SPIO) and for clinically N0 early oral cancer.
Materials and methods |
MRL using SPIO and SLNB with the handheld cordless magnetic probe were performed for 27 patients with clinically N0 early oral cancer.
Results |
In all 27 patients (100%), SLNs were detected by MRL, and the total and mean number of SLNs were 73 and 2.7, respectively. All SLNs identified by MRL were detectable using the magnetic probe in all patients.
Conclusions |
SLNB with handheld cordless magnetic probe following preoperative SLN mapping by MRL using SPIO is feasible, without RI use, for neck management in cases of clinically N0 early oral cancer.
Le texte complet de cet article est disponible en PDF.Keywords : Early oral cancer, Magnetic resonance lymphography, Magnetic probe, Sentinel lymph node, Sentinel lymph node biopsy, Superparamagnetic iron oxide
Plan
Vol 123 - N° 5
P. 521-526 - octobre 2022 Retour au numéroBienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.
Déjà abonné à cette revue ?