S'abonner

Clinical and radiological results after revision THA with distal locking stem: A cohort study of 44 patients - 27/09/22

Doi : 10.1016/j.otsr.2022.103267 
Lou Lequeuche, Az-Eddine Djebara , Yassine Bulaïd, Massinissa Deh, Antoine Gabrion, Patrice Mertl
 Service de Chirurgie Orthopédique et Traumatologie, CHU Amiens-Picardie, 80480, Salouël, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Distal locking stems were developed in response to some complex revision procedures in total hip arthroplasty (THA), providing better axial and rotational stability. The aim of the present study was to assess medium-term clinical and radiological results of treatment with last-generation distal locking stem.

Hypothesis

Our hypothesis was that this implant provided a high survival rate.

Material and Methods

A single-center retrospective observational study included all patients who underwent THA revision with distal locking stem between April 2013 and January 2015 in our university hospital. The implant was a curved distal-locking stem fully coated in grit-blasted titanium alloy and hydroxyapatite (HA) with a collar made of TiAlV. This concept is based on primary distal fixation by interlocking screws. The primary endpoint was surgical revision for implant exchange.

Results

A total of 47 procedures with distal locking stem were performed, 44 of which were included. Minimum follow-up was 5 years. Etiologies of revision comprised 25 femoral loosenings, 13 periprosthetic fractures, 3 infections, and 3 modular taper breakages. Six patients underwent re-revision (13%), with only 1 implant change (98% survival rate). Mean Harris and Oxford Hip scores at last follow-up were respectively 81±13.5 [range, 67.4–94.5] and 26±9⋅2 [range, 16.7–35.2]. Radiologically, no stem subsidence occurred, and bone ingrowth was obtained in all cases.

Discussion

Fully-coated distal locking stems showed a high survival rate. They provided strong initial fixation, allowing early full weight-bearing in these frail patients.

Level of evidence

IV; retrospective series.

Le texte complet de cet article est disponible en PDF.

Keywords : Revision, Total hip replacement, Locking stem, Uncemented


Plan


© 2022  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 108 - N° 6

Article 103267- octobre 2022 Retour au numéro
Article précédent Article précédent
  • Short stature and short distance between the anterior acetabular rim to the femoral nerve are risk factors for femoral nerve palsy following primary total hip arthroplasty using the modified Watson-Jones approach
  • Naoto Watanabe, Ryohei Takada, Takahisa Ogawa, Kazumasa Miyatake, Masanobu Hirao, Chisato Hoshino, Tetsuya Jinno, Hideyuki Koga, Toshitaka Yoshii, Atsushi Okawa
| Article suivant Article suivant
  • Fully hydroxyapatite-coated distal locking cementless femoral modular implant for revision total hip arthroplasty: A retrospective study of 94 Renaissance™ stems at a minimum 10 years’ follow-up
  • Fabien Slomka, Jérôme Druon, Philippe Rosset, Louis-Romée Le Nail

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.