S'abonner

The impact of inhaler technique on clinical outcomes in adolescents and adults with asthma: A systematic review - 23/09/22

Doi : 10.1016/j.rmed.2022.106949 
N. Roche a, , B. Aggarwal b, I. Boucot c, L. Mittal d, A. Martin d, H. Chrystyn e
a Hôpital Cochin, AP-HP. Centre-Université de Paris, Paris, France 
b GSK, Singapore, 139234, Singapore 
c GSK, Brentford, Middlesex, UK 
d Evidera, Needham, MA, USA 
e Inhalation Consultancy, Leeds, UK 

Corresponding author.

Abstract

Background

Many patients with asthma use their inhalers incorrectly, which can lead to sub-optimal asthma control and an increased risk of exacerbations. The Accuhaler/Diskus and Turbuhaler are arguably two of the most commonly used dry powder inhalers worldwide.

Methods

A systematic literature review (SLR) was conducted to assess the impact of inhalation errors with these dry powder inhalers on clinical outcomes in asthma. Database searches were conducted in MEDLINE, Embase and proceedings from scientific conferences. Observational studies in adults and adolescents with asthma, reporting data for Accuhaler/Diskus and Turbuhaler devices and at least one outcome of interest, were included. Dual-independent screening and validation of studies was performed.

Results

The search identified 35 studies. A range of inhaler errors was observed across studies and devices. In 8 out of the 9 studies that involved the two devices, the percentage of overall inhaler error rates was numerically (7 studies) or significantly (1 study) higher for Turbuhaler than Diskus, ranging from 3.7% to 71.9% for Diskus and 1.2%–83% for Turbuhaler. Critical errors, reported in three studies using similar definitions, ranged from 20% to 43% for Diskus and 32%–100% for Turbuhaler. Five studies reported a significant association between inhaler errors and worse asthma control, while one showed no difference.

Conclusions

This SLR identified a large range of inhaler errors with both devices. Across devices, a better inhalation technique was associated with better asthma outcomes. This systematic review confirms the importance of patients using their inhalers correctly as an integral part of achieving optimal asthma outcomes.

Le texte complet de cet article est disponible en PDF.

Highlights

Inhaler errors are common in patients with asthma and are linked to worse outcomes.
A large range of inhaler errors was reported for both Diskus and Turbuhaler devices.
Across devices, a better technique was associated with better asthma outcomes.
Further, standardised data collection and analysis on inhaler errors is required.

Le texte complet de cet article est disponible en PDF.

Keywords : Asthma, Diskus, Inhaler errors, Clinical outcomes


Plan


© 2022  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 202

Article 106949- octobre 2022 Retour au numéro
Article suivant Article suivant
  • Does baricitinib reduce mortality and disease progression in SARS-CoV-2 virus infected patients? A systematic review and meta analysis
  • Sivananthan Manoharan, Lee Ying Ying

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.