S'abonner

Oviduct-mimicking microfluidic chips decreased the ROS concentration in the in vitro fertilized embryos of CD-1 mice - 10/09/22

Doi : 10.1016/j.biopha.2022.113567 
Meng Wang a, 1, Tingting Zhu b, 1, Chang Liu c, Lei Jin a, Peng Fei b, 2, Bo Zhang a, , 2
a Reproductive Medicine Center, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China 
b School of Optical and Electronic Information, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, China 
c Reproductive Medicine Center, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, China 

Correspondence to: Reproductive Medicine Center, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China.Reproductive Medicine Center, Tongji Hospital, Tongji Medical College, Huazhong University of Science and TechnologyWuhan430030China

Abstract

Background

The process of the assisted reproductive technology (ART) cycle is extremely complicated, and various factors in each step may influence the final clinical outcomes; thus, optimizing culture conditions for embryos is crucial in the ART cycle, particularly when the traditional petri-dish method remains unchanged for decades. In the current study, we intend to culture embryos in a dynamic environment on chips to optimize the embryo culture conditions.

Methods

Multilayer soft lithography technology was utilized to establish a microfluidics-based oviduct. Mouse primary oviduct epithelial cells were identified by immunofluorescence staining and then loaded into the chip to coculture with the embryos. The development potential parameters of embryos on chips with cells, on chips without cells, and in drops were compared, as well as reactive oxygen species (ROS) in embryos.

Results

There were no obvious differences regarding the fertilization rate, 4-Cell embryo rate, cleavage rate, high-quality embryo rate, or blastocyst formation rate. However, the intracellular ROS levels in 4-Cell stage embryos on chips with cells were statistically significantly lower than those in drops (P < 0.001). This organ-on-chip device allowed the probability of mammalian embryo culture in a microfluidic-based manner.

Conclusions

Our findings demonstrated that this novel oviduct-on-chip model may optimize embryo culture conditions by reducing intracellular ROS levels, which may be a competent alternative to the existing stable embryo culture system.

Le texte complet de cet article est disponible en PDF.

Keywords : Microfluidic, Oviduct, Embryo culture, Reactive oxygen species, Organ-on-chip


Plan


© 2022  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 154

Article 113567- octobre 2022 Retour au numéro
Article précédent Article précédent
  • Verapamil hydrochloride loaded solid lipid nanoparticles: Preparation, optimization, characterisation, and assessment of cardioprotective effect in experimental model of myocardial infarcted rats
  • Yogeeta.O. Agrawal, Muzammil Husain, Kiran D. Patil, Vishal Sodgir, Tulshidas S. Patil, Vinit V. Agnihotri, Hitendra S. Mahajan, Charu Sharma, Shreesh Ojha, Sameer N. Goyal
| Article suivant Article suivant
  • Construction of magnetic drug delivery system and its potential application in tumor theranostics
  • Mingrui Jiang, Qianqian Liu, Yu Zhang, Huinan Wang, Jingqiu Zhang, Mengyu Chen, Zhuzhu Yue, Zhicheng Wang, Xiaotong Wei, Shuanghui Shi, Menglin Wang, Yanglong Hou, Zhiyi Wang, Fugeng Sheng, Ning Tian, Yingzi Wang

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.