Automating DUID methods using robotics for rapid high throughput sample preparation – Section 4 and Section 5A UK Road Traffic Act Compounds in Whole Blood - 15/08/22

Doi : 10.1016/j.toxac.2022.06.235 
Aaron Mcmillan , Mark Evans, Dionne Lawrence, Alongi Talia, Tian Bu, Mark Parkin, Grosse Susan
 Toxicology, Eurofins forensic services, London, United Kingdom 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Aim

To fully automate a 96-well plate sample preparation technique using liquid handling robotics for the purpose of significantly increasing sample throughput for whole blood samples taken under the UK Road Traffic Act (RTA).

Introduction: demand for analysis of whole blood samples taken under the Road Traffic Act 1988 has increased in recent years due to UK Policing and Government policy on tackling driving under the influence of drugs (DUID). Previous extraction techniques utilised by our laboratory include manual or semi-automated approaches that are lengthy and labour intensive. Both approaches require time consuming human input, to precipitate blood and prepare calibrators and quality controls. Recent developments have sped up chromatographic methods through use of techniques such as ultra-high performance liquid chromatography. However, there has been little progress with speeding up sample preparation and extraction processes, particularly for whole blood to compliment increased LC-MS/MS capacity. Use of 96-well plate formats for protein precipitation and extraction provide a platform that can be readily coupled to automated liquid handling (ALH) instruments. This provides a solution to the increase in demand by allowing for extraction of more samples, with minimal human input, in a much shorter amount of time. Here we present development, validation and implementation of an automated robotic sample preparation method for whole blood for analysis of drugs in RTA cases.

Method

Aliquots (200μL) of blank blood and casework samples were dispensed into a 96-well plate using a robotic pipetting system before being loaded onto a Hamilton ALH. Casework samples and blank blood were spiked with internal standard. Additional blank blood samples were further spiked to produce calibrants and quality controls. The plate was mixed with the addition of a cell lysis solution and the aliquots transferred to a protein/lipid depletion (PPT) plate. A positive pressure manifold was used to draw the solution through the PPT plate into a collection plate where the precipitate was dried. The precipitate was reconstituted and loaded by the Hamilton onto a microelution SPE plate. Following extraction, the samples were reconstituted and the collection plate placed in the LC-MS/MS autosampler for analysis. The LC-MS/MS method consists of a 2.1mm×30mm, 1.7μm, C18 column running a 4minute gradient of water and methanol with 0.1% formic acid.

Results

Quantitation of 34 compounds (including common drugs of abuse and their metabolites) was successfully validated with CVs ranging from 3.0%–9.0% and accuracies of 85.8%–111.7%. Within batch precision had CVs of<10.0%. The robotic platform was able to undertake sample pre-treatment and extraction of 40 case samples in 3.5hours. The method was implemented into casework following UKAS accreditation and in 2021, 12,400 samples were analysed using the method.

Introduction of this method to our laboratory has resulted in a significant increase in speed for a sample to be processed and results obtained. Each ALH is capable of extracting two batches per day; equating to 160 case sample versus 28 cases on semi-automated methods. This, along with a reduced sample volume requirement and reduced solvent consumption has had a very beneficial impact in terms of cost, turnaround times and ability to use low sample volume cases.

Conclusion

Full automation of sample preparation of whole blood samples coupled with high speed chromatographic techniques can significantly increase throughput, decrease turnaround times and reduce solvent consumption.

Le texte complet de cet article est disponible en PDF.

Plan


© 2022  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 34 - N° 3S

P. S141 - septembre 2022 Retour au numéro
Article précédent Article précédent
  • The impact of imidacloprid and its metabolites on long-term neurodevelopmental and neurodegenerative disorders in a Zebrafish model
  • Megan Mcculloch, Lerato Homu, Carine Smith, Tracy Kellermann
| Article suivant Article suivant
  • Multi-panel detection of drugs and drug metabolites in hair samples using a comprehensive extraction method
  • Daniel Mcmillan, Pierre Negri, Samuele Scurati, Valentina Longo

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.